Installation Manual

THALES COMMUNICATIONS
OIM
AHV1600-SYSTEM
Page 207
July 16/09
C. COOLING OF THE EQUIPMENT
The AHV1600 on platform installation must take into account that heat dissipation for the Trans-
ceiver is partially accomplished through natural convection requiring a minimum space between the
Transceiver and the next equipment of 10 mm.
The remained part of the heat is dissipated by conduction between the bottom part of the Trans-
ceiver chassis and the platform frame. The maximum heat dissipation is 20 watts.
D. HANDLING
No specific tools or support are required to handle or carry the Transceiver due to its small and pre-
hensile dimensions and its lightweight.
The Transceiver is equipped with caps, which are plugged on each I/O connector, and which pro-
tect them from ESD, sand and dust.
5. EQUIPMENT INPUTS / OUTPUTS
A. MAIN CONNECTOR J1
Socket
Contact
Contact
Gauge
Input (I) /
Output (O)
Signal Name Wire Type
Installation Require-
ments
1 22D Reserved
2 22D Reserved
3 22D Reserved
4 22D Reserved
5 22D I FCT_TST Simple see note 4 Discrete input signal
6 22D I TST_INH Simple see note 4 Discrete input signal
7 22D Reserved
8 22D Reserved
9 22D O TX429_HI_1
Twisted/Shielded see
note 2&3
Differential output serial
line
10 22D O TX429_HI_1
Twisted/Shielded see
note 2&3
Differential output serial
line
11 22D Reserved