Cinterion® Device Gateway LTE Hardware Interface Description Version: DocId: 09a DGL61-W_HID_v09a
Cinterion® DGL61-W Hardware Interface Description Page 2 of 45 2 Document Name: Cinterion® DGL61-W Hardware Interface Description Version: 09a Date: 2021-04-14 DocId: DGL61-W_HID_v09a Status Public / Released GENERAL NOTE THIS DOCUMENT CONTAINS INFORMATION ON THALES DIS AIS DEUTSCHLAND GMBH (“THALES”) PRODUCTS. THALES RESERVES THE RIGHT TO MAKE CHANGES TO THE PRODUCTS DESCRIBED HEREIN. THE SPECIFICATIONS IN THIS DOCUMENT ARE SUBJECT TO CHANGE AT THE DISCRETION OF THALES.
Cinterion® DGL61-W Hardware Interface Description Page 3 of 45 Contents 45 Contents 0 Document History ...................................................................................................... 7 1 Introduction ............................................................................................................... 10 1.1 Related Documents ......................................................................................... 10 1.2 Terms and Abbreviations .........................
Cinterion® DGL61-W Hardware Interface Description Page 4 of 45 Contents 45 6 Mechanics, Mounting and Packaging ..................................................................... 37 6.1 Mechanical Dimensions ................................................................................... 37 6.2 Mounting Clip (optional) ................................................................................... 38 6.3 Packaging .................................................................................
Cinterion® DGL61-W Hardware Interface Description Page 5 of 45 Tables Tables Table 1: Table 2: Table 3: Table 4: Table 5: Table 6: Table 7: Table 8: Table 9: Table 10: Table 11: Table 12: Table 13: Table 14: Table 15: Table 16: Table 17: Table 18: Terms and abbreviations................................................................................. 11 Directives ........................................................................................................
Cinterion® DGL61-W Hardware Interface Description Page 6 of 45 Figures Figures Figure 1: Figure 2: Figure 3: Figure 4: Figure 5: Figure 6: Figure 7: Figure 8: Figure 9: Figure 10: Figure 11: Figure 12: Figure 13: Sample Device Gateway LTE label DGL61-W................................................ 18 Installed USB devices ..................................................................................... 23 Connection via USB interface (USB modem) .................................................
Cinterion® DGL61-W Hardware Interface Description Page 7 of 45 0 Document History 9 0 Document History Preceding Document: Cinterion® Device Gateway LTE Hardware Interface Description" Version 09 New document: "Cinterion® Device Gateway LTE Hardware Interface Description" Version 09a Chapter What is new 5.3 Revised Table 14 regarding RF output tolerance of Band 2 7.
Cinterion® DGL61-W Hardware Interface Description Page 8 of 45 0 Document History 9 Preceding Document: Cinterion® Device Gateway LTE Hardware Interface Description" Version 05 New document: "Cinterion® Device Gateway LTE Hardware Interface Description" Version 06 Chapter What is new 1.3.1 Revised standards and versions in Table 3 and Table 4 3.2 Revised chapter (product and company name) 7.
Cinterion® DGL61-W Hardware Interface Description Page 9 of 45 0 Document History 9 Preceding Document: Cinterion® Device Gateway LTE Hardware Interface Description" Version 01 New document: "Cinterion® Device Gateway LTE Hardware Interface Description" Version 02 Chapter What is new 4.10 Changed sequence of LEDs in Figure 9 New document: "Cinterion® Device Gateway LTE Hardware Interface Description" Version 01 Chapter What is new -- Initial document setup.
Cinterion® DGL61-W Hardware Interface Description Page 10 of 45 1 Introduction 18 1 Introduction This document1 describes the hardware of the Cinterion® Device Gateway LTE: • DGL61-W implements a USB 2.0 interface with a USB-A connector The Device Gateway LTE contains a Cinterion® PLS62-W Java module with internal antennas and has a fixed connected USB 2.0 cable with a USB-A connector.
Cinterion® DGL61-W Hardware Interface Description Page 11 of 45 1.2 Terms and Abbreviations 18 1.
Cinterion® DGL61-W Hardware Interface Description Page 12 of 45 1.
Cinterion® DGL61-W Hardware Interface Description Page 13 of 45 1.3 Regulatory and Type Approval Information 18 1.3 Regulatory and Type Approval Information 1.3.1 Directives and Standards Device Gateway LTE have been designed to comply with the directives and standards listed below.
Cinterion® DGL61-W Hardware Interface Description Page 14 of 45 1.3 Regulatory and Type Approval Information 18 Table 4: Standards of European type approval 3GPP TS 51.010-1 “Digital cellular telecommunications system (Phase 2); Mobile Station (MS) conformance specification” ETSI EN 301 511 V12.5.1 Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonized Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU ETSI EN 301 489-1 V2.1.
Cinterion® DGL61-W Hardware Interface Description Page 15 of 45 1.3 Regulatory and Type Approval Information 18 Table 6: Standards of the Ministry of Information Industry of the People’s Republic of China SJ/T 11363-2006 “Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products” (2006-06). SJ/T 11364-2006 “Marking for Control of Pollution Caused by Electronic Information Products” (2006-06).
Cinterion® DGL61-W Hardware Interface Description Page 16 of 45 1.3 Regulatory and Type Approval Information 18 1.3.2 Safety Precautions The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating Device Gateway LTE.
Cinterion® DGL61-W Hardware Interface Description Page 17 of 45 1.3 Regulatory and Type Approval Information 18 IMPORTANT! Cellular terminals or mobiles operate using radio signals and cellular networks. In that case connections cannot be guaranteed at all times under all conditions. Therefore, you should never rely solely upon any wireless device for essential communications, for example emergency calls.
Cinterion® DGL61-W Hardware Interface Description Page 18 of 45 1.4 Product Label 18 1.4 Product Label The label fixed to the bottom of a Device Gateway LTE comprises the following information. 1 Werinherstr. 81, 81541 Munich, Germany 2 15 3 4 14 5 13 12 9 10 7 8 11 6 Figure 1: Sample Device Gateway LTE label DGL61-W Table 8: Device Gateway LTE label information No.
Cinterion® DGL61-W Hardware Interface Description Page 19 of 45 2 Product Concept 21 2 Product Concept 2.1 Key Features at a Glance Feature Implementation General Incorporates Cinterion® PLS62-W Java module The PLS62-W Java module handles all signal and data processing within the Device Gateway LTE. Internal software runs the application interface and the complete LTE/UMTS/GSM protocol stack.
Cinterion® DGL61-W Hardware Interface Description Page 20 of 45 2.
Cinterion® DGL61-W Hardware Interface Description Page 21 of 45 2.1 Key Features at a Glance 21 Feature Implementation TCP/IP stack Protocols: TCP server/client, UDP, DNS, Ping, HTTP, FTP, SMTP Access by AT commands Firmware update Upgradeable via USB interface Antenna two internal antennas for maximum RF performance Interfaces USB interface USB 2.0 Slave interface, cable length 200 mm SIM card reader Supported micro SIM cards: 3V, 1.
Cinterion® DGL61-W Hardware Interface Description Page 22 of 45 3 Getting Started with DGL61-W 23 3 Getting Started with DGL61-W 3.1 Technical Requirements for Using DGL61-W • • • • • • Device Gateway LTE DGL61-W. micro SIM Card and PIN, if SIM card is PIN protected Thales PLS62-W USB driver package Computer running Windows 7 (or Windows 8 or Windows 10), USB 2.
Cinterion® DGL61-W Hardware Interface Description Page 23 of 45 3.2 Start Up the DGL61-W 23 Figure 2: Installed USB devices • To connect to the DGL61-W via USB interface, check the properties of the enumerated USB devices for the configured COM ports, for example the "Cinterion PLSx USB Modem", call a terminal program on the PC and connect to the configured COM port. Type the AT command ATI to display module identification information.
Cinterion® DGL61-W Hardware Interface Description Page 24 of 45 4 Interface Description 32 4 Interface Description 4.1 Overview Device Gateway LTE provide the following interfaces for power supply/ data transfer and micro SIM card: Table 9: Device Gateway LTE‘ interfaces No. 1 2 3 Description USB 2.
Cinterion® DGL61-W Hardware Interface Description Page 25 of 45 4.2 Block Diagram 32 4.2 Block Diagram Figure 5 shows a block diagram of a sample configuration that incorporates a Device Gateway and typical accessories.
Cinterion® DGL61-W Hardware Interface Description Page 26 of 45 4.
Cinterion® DGL61-W Hardware Interface Description Page 27 of 45 4.
Cinterion® DGL61-W Hardware Interface Description Page 28 of 45 4.3 Operating Modes 32 4.3 Operating Modes The table below briefly summarizes the various operating modes referred to in the following chapters. Table 10: Overview of operating modes Normal operation GSM IDLE Software is active. Once registered to the GSM network paging with BTS is carried out. The Device Gateway is ready to send and receive. GSM DATA Connection between two subscribers is in progress.
Cinterion® DGL61-W Hardware Interface Description Page 29 of 45 4.5 Power Supply 32 4.5 Power Supply The DGL61-W power supply via USB has to be a single voltage source of 5V DC. When power fails for >1ms, DGL61-W safely power down and restarts when power is back and valid. The RTC doesn't support longer power fails, this will reset he RTC. 4.
Cinterion® DGL61-W Hardware Interface Description Page 30 of 45 4.7 Automatic thermal shutdown 32 4.6.4 Disconnecting power supply The DGL61-W can be disconnected at any time because the DGL61-W is protected against sudden power loss (USB disconnection). 4.7 Automatic thermal shutdown An on-board NTC measures the temperature of the built-in Java module. If over- or under-temperature is detected on the module the DGL61-W automatically reseted to avoid thermal damage to the system.
Cinterion® DGL61-W Hardware Interface Description Page 31 of 45 4.9 SIM Interface 32 4.9 SIM Interface The SIM interface is intended for 1.8V and 3V micro SIM cards in accordance with GSM 11.12 Phase 2. The card holder is a five wire interface according to GSM 11.11. A sixth pin has been added to detect whether or not a SIM card is inserted.
Cinterion® DGL61-W Hardware Interface Description Page 32 of 45 4.10 Status LEDs 32 4.10 Status LEDs Device Gateway LTE has four LEDs indicating its operating states: • A green LED indicates whether the Device Gateway LTE is powered or not • A green LED indicates the network registration state of the Device Gateway LTE. • A green LED, off by default, FW controlled by AT commands or midlet only, for customer purpose like service status (2G: off, 3G/4G: on).
Cinterion® DGL61-W Hardware Interface Description Page 33 of 45 5 Electrical and Environmental Characteristics 36 5 Electrical and Environmental Characteristics 5.1 Absolute Maximum Ratings Table 11: Absolute maximum ratings Parameter Port / Description Min. Supply voltage USB interface All electrical characteristics according to -USB Implementers' Forum, USB 2.0 Specification. Immunity against discharge of static electricity SIM Interface Contact discharge Air discharge 5.2 -4 -8 Max.
Cinterion® DGL61-W Hardware Interface Description Page 34 of 45 5.4 USB Interface 36 Table 14: RF Output Power Technology RF Output Power UMTS Output power (according to Release 8) Class 3 (+24dBm +1/-3dB) for UMTS 800, WCDMA FDD BdXIX Class 3 (+24dBm +1/-3dB) for UMTS 850, WCDMA FDD BdV Class 3 (+24dBm +1/-3dB) for UMTS 900, WCDMA FDD BdVIII Class 3 (+23.8dBm +0.1/-2.8dB) for UMTS AWS, WCDMA FDD BdIV Class 3 (+24dBm +1/-3dB) for UMTS 1800, WCDMA FDD BdIX Class 3 (+24dBm +0.
Cinterion® DGL61-W Hardware Interface Description Page 35 of 45 5.5 Operating Temperatures 36 5.5 Operating Temperatures Table 15: Temperature characteristics Parameter Min Normal (unlimited) Operation -30 Typical Extended Operation Automatic thermal restart 3,4 <-40 Max Unit +50°C °C +601 to +702 °C >+90 °C 1. Maximum time to transmit to keep DGL61-W below the automatic thermal restart limit.
Cinterion® DGL61-W Hardware Interface Description Page 36 of 45 5.6 Storage Conditions 36 5.6 Storage Conditions Table 16: Storage conditions Type Condition Unit Reference Air temperature: Low High -30 +75 °C ETS 300 019-2-1: T1.2, IEC 60068-2-1 Ab ETS 300 019-2-1: T1.2, IEC 60068-2-2 Bb Humidity relative: Low High Condens. 10 90 at 30°C 90-100 at 30°C % --ETS 300 019-2-1: T1.2, IEC 60068-2-56 Cb ETS 300 019-2-1: T1.
Cinterion® DGL61-W Hardware Interface Description Page 37 of 45 6 Mechanics, Mounting and Packaging 39 6 Mechanics, Mounting and Packaging 6.1 Mechanical Dimensions Figure 10 shows a 3D view of the Device Gateway and provides an overview of the mechanical dimensions of the device. For further details see Figure 11 and Section 6.3. To allow for an easier mechanical implementation into an external application 3D STP data for the Device Gateway is attached to this PDF.
Cinterion® DGL61-W Hardware Interface Description Page 38 of 45 6.2 Mounting Clip (optional) 39 73.5 mm 114.5 mm 19.5 mm Figure 11: Device Gateway LTE mechanical dimensions 6.2 Mounting Clip (optional) For mounting the DGL61-W there is a mounting clip available (see Figure 12). Length: Width: Height: 119.25 mm 69.0 mm 15.7 mm Weight: t.b.d. g Figure 12: DGL61-W Mounting Clip For ordering information of DGL61-W Mounting Clip please refer to Chapter 8.
Cinterion® DGL61-W Hardware Interface Description Page 39 of 45 6.3 Packaging 39 6.
Cinterion® DGL61-W Hardware Interface Description Page 40 of 45 7 Full Type Approval 43 7 Full Type Approval 7.1 Thales Reference Setup The Thales reference setup submitted to type approve Device Gateway LTE consists of the following components: • • Device Gateway LTE with approved Java module PC as MMI and Power Supply PC (5V / 1A on USB ) USB Device Gateway LTE micro SIM Figure 13: Reference equipment for approval For ordering information of DGL61-W please refer to Chapter 8.
Cinterion® DGL61-W Hardware Interface Description Page 41 of 45 7.2 Restrictions 43 7.2 Restrictions Later enhancements and modifications beyond the certified configuration require extra approvals. Each supplementary approval process includes submittal of the technical documentation as well as testing of the changes made. • No further approvals are required for customer applications that comply with the approved DGL61-W configuration.
Cinterion® DGL61-W Hardware Interface Description Page 42 of 45 7.6 Compliance with FCC and ISED Rules and Regulations 43 7.6 Compliance with FCC and ISED Rules and Regulations As an integrated product, the Device Gateway LTE DGL61-W is fully compliant with the grant of the FCC Equipment Authorization and the ISED Certificates issued for the built-in Java modules, and therefore, bear the labels “Contains FCC ID: QIPPLS62-W”, and accordingly “Contains IC: 7830A-PLS62W“.
Cinterion® DGL61-W Hardware Interface Description Page 43 of 45 7.6 Compliance with FCC and ISED Rules and Regulations 43 Please contact us for more information on the FCC Compliance details mentioned above: Thales Edgar Canizales Arboretum Plaza II 9442 Capital of Texas Highway, Suite 400 Austin, TX 78759 Tel: +1 512 215 7326 Email: edgar.canizales@thalesgroup.com Notes (ISED): (EN) This Class B digital apparatus complies with Canadian ICES-003 and RSS-210.
Cinterion® DGL61-W Hardware Interface Description Page 44 of 45 8 Ordering Information 44 8 Ordering Information Table 18: Ordering Information Description Supplier Ordering information DGL61-W Thales L30960-N6800-A100 USB Cable length: 200mm Other USB Cable length (0.5m, 1m) on request DGL61-W Mounting Clip t Thales t.b.d.
THALES DIS AIS Deutschland GmbH Werinherstrasse 81 81541 Munich Germany © Thales 2021. All rights reserved. Thales, the Thales logo, are trademarks and service marks of Thales and are registered in certain countries.