GPS Receiver User Guide

116 ProMark2 Users Guide
Point Attribute - Kinematic Screen
The Point Attribute - Kinematic screen, Figure 4.9, lets you set and save point attribute
information when kinematic mode is selected. Table 4.6 describes the screen parameters.
Figure 4.9 Point Attribute - Kinematic Screen
Table 4.6 Point Attribute - Kinematic Screen Parameters
Parameter Description
Site ID Lets you enter a 4-character alphanumeric site ID. Valid characters are all characters except for
space, < > : and \. If an illegal character is entered, it will automatically be replaced by – (dash).
The default entry is 0001. Entering “1” will display “0001”.
Site
Description
Calls the Site Description screen where you can select a descriptor from the descriptor list, enter a
new descriptor of up to 20 characters, edit a descriptor, and delete a descriptor. The default is blank.
Initialize Calls the Init Mode screen where you can set the occupation as an initialization point on an
initializer bar or a known point. Set to <None> if no initialization is desired. If the initializer bar or
known point is selected, the Time on Site field will be displayed beside the site ID. Default time on
site for bar is 300 seconds. Default time-on-site value for known point is 15 seconds. The known
point will only be available if a control point has been logged in stop-and-go mode.
Save Saves settings.
Note: After a power cycle, all parameters set will be saved with the exception of the Initialize field which will revert to the default
value None.
Note: Site description information is shared by the three modes of operation. So site descriptions added, edited or deleted in any of
the other modes will reflect when in the other modes. The same is true for site ID and time on site.