User Manual Part 1

IS-900 User Guide Page 42 of 159
With each SoniStrip angled at 45 degrees toward the screen center, the normal vectors for the
installation and wiring shown in Figure 19 become:
SoniDisc ID Nos. Normal Vectors used in Constellation Array
5001 5003 -0.707, 0.707, 0.000
5004 5009 -0.707, 0.000, 0.707
5010 5012 -0.707, -0.707, 0.000
5013 5018 -0.707, 0.000, -0.707
3.3.3. SoniStrip Mounting for CAVE-like Installations
The following is an example of an installation for a typical CAVE-like environment.
The IS-900 excels over magnetic or optical trackers in CAVE-like installations. As shown in
Figure 20, the SoniStrips are positioned to provide uniform tracking coverage throughout the
entire immersive display environment with no distortion or occlusion issues.
3 meters
3 meters
Mirror
SoniStrips Mounted at
45 degree angles
Additional Mounting Support
IS-900 Processor
5001
5002
5003
5004
5005 5006
5009
5008
5007
5013
5014
5015
5018
5017
5016
5012 5011 5010
+ X
+ Y
+ Z
into floor
Figure 20 - CAVE-like Installation (top down view)
The example above is a 3 meter cube, 4 walled immersive display system which uses six 6-ft.
SoniStrips. Depending of the number of display walls, display volume and mirror position/size, it
may be necessary to use a variety of different sized SoniStrips (6, 4, and 2 foot) or SoniPods
discretely located to provide the optimum tracking coverage. Please consult with InterSense
regarding all CAVE-like installations to maximize the tracking performance.