User Manual Part 1

IS-900 User Guide Page 60 of 159
OFF A connection has not been established with a Wireless Transmitter Module.
Charging Instructions
Only use the power supply from InterSense when charging the Radio/Battery
board. Other chargers could cause failures. See the battery handling
instructions at the beginning of this manual.
When the “Low Power” LED on the Transmitter Module is ON or when you want to make sure
that the module is fully charged, you should connect the Transmitter Module to the charger. You
may leave the Transmitter Module on while charging; but, if you plan on using another
Transmitter Module Base Receiver Module pair with the same channel selected, you must turn
off the Wireless Transmitter Module while it is being charged.
While it is charging the LED next to the charger port will be on (Orange). When it turns solid
Green, the battery is finished charging (flashing green indicated that the battery is being “topped
off”. A fully discharged battery takes less than 4 hours to charge. If the green charging LED does
not turn off after 6 hours, there may be a problem. Please disconnect the charger and contact
technical support.
Changing a MicroTrax head tracking device from a wireless to wired configuration
To convert the MicroTrax devices from wireless to wired mode, follow these steps:
1. Turn off the IS-900 processor
2. Disconnect the appropriate receiver cable from the IS-900 Processor to the Base Receiver
Module.
3. Turn off the power on the Wireless Transmitter Module connected to the MicroTrax device.
4. Unplug the MicroTrax device from the Transmitter Module and plug it into the MicroTrax IS-
900 Wired Adapter device.
5. Connect the wired adapter in the IS-900 Processor and turn the power on. No software or
configuration will need to be changed.