IS-900 User Guide Page 64 of 159
Parity N
bits 8
HHS OFF
System Record Request S Request a system status record to be sent.
Station Status l{stationNum},[state]<> Set the stationNum on or off.
state 0 = OFF, 1 = ON
Default All connected stations are on
Output Units Control U Sets output data record position units to inches.
u Sets the position units to centimeters. These only
matter in 6-DOF mode.
Default U
System control ^K Save the current settings to nonvolatile memory.
W Restore the system settings to the factory
defaults.
^Y Restart the firmware to the power up condition.
^S Suspend data transmission.
^Q Resume data transmission.
Caution: Sending W command will cause all the user
configuration information to be lost.
Output record mode F Put in ASCII output mode
f Put in Binary output mode.
Default F