IS-900 User Guide Page 70 of 159
Set Ethernet Communication Parameters
MEthIp[address]<> Sets System IP address.
Use dotted format like 192.168.1.1. If address is omitted,
the current address is returned, 31EI[address]<>. The IP
address takes effect immediately unless an address was
already set, in which case system settings must be saved
and the system must be restarted.
MEthUdp[state]<> Sets state of UDP broadcast.
state=1 to enable, state=2 to disable (default).
MEthUdpPort[port]<> Sets UDP broadcast port.
Default Ethernet communications settings:
UDP state OFF
UDP port 5001
IP address None
InterSense System Status Record Request
MS<> Request the manufacturer-specific system status
record. This is information about parameters which
are specific to the InterSense product, additional to
the standard system status information obtained
using the S command.
Tracking Status Record Request
MP<> Requests tracking status information for all 12
stations. See Section 5.5.5 for the description.
Ultrasonic Timeout Interval
MU[interval]<> This command has no effect with the IS-
900.
Default N/A
Ultrasonic Receiver Sensitivity
Mg[Level]<> This command has no effect with the IS-900.
Default N/A