User Manual Part 2

IS-900 User Guide Page 83 of 159
8.5.4. InterSense-specific Records
Manufacturer System Status Record
This record is sent in response to an MS<> command. It
returns a status record specific to the InterSense system.
31S{statusRecord}<>
Bytes Explanation
1 Record type , '3'
2 Station number. Always '1'
3 Sub-Record type, 'S'
4 Config Hex Char 0
5 Config Hex Char 1
6 Config Hex Char 2
7,8 CR, LF
To decode each of the Config Hex Characters
Config Hex Char 0 Reserved
Config Hex Char 1 Reserved
Config Hex Char 2
Bit Meaning
0 Reserved
1 Boresight Compatibility Mode (0 = Firmware Version
2.x, 1 = FASTRACK)
2 Time units (0 = milliseconds, 1 = microseconds)
3 ReceiverPod LEDs (0 = OFF, 1 = ON)
Manufacturer Station Record
This record is sent in response to the Ms{stationNum}<>
command. It returns a station status record specific to the
InterSense system.
3{stationNum}s{statusRecord}<>
Bytes Explanation
1 Record type , '3'
2 Station number. A hexadecimal number up to C.
3 Sub-Record type, 's'
4 Config Byte 0
5 Config Byte 1
6 Config Byte 2
7,8 CR, LF