User Manual Part 2

IS-900 User Guide Page 152 of 159
SyncState
Applies to IS-X Series devices only. Can be one of 4 values:
0 - OFF, system is in free run
1 Unknown State
2 - ON, hardware genlock frequency is specified by the user
3 - ON, no hardware signal, lock to the user specified frequency
SyncRate
Sync frequency - number of hardware sync signals per second, or, if SyncState
is 3 - data record output frequency.
SyncPhase
The time within the sync period at which a data record is transmitted. The phase
point is specified as a percentage of the sync period. 0% (the default) instructs
the tracker to output a data record as soon as possible after the sync period
begins. 100% delays the output of a record as much as possible before the next
sync period begins.
Interface
Hardware interface type, as defined in ISD_INTERFACE_TYPE.
UltTimeout
IS-900 only, ultrasonic timeout (sampling rate).
UltVolume
IS-900 only, ultrasonic speaker volume.
LedEnable
IS-900 only, blue led on the SoniDiscs enable flag.