User's Manual

Table Of Contents
InterSense Doc. No. 072-00105-0I07 Rev. 4.2
IS-900 User Guide Page 140 of 177
The Constellation 3D tool also includes a three dimensional
performance tool. This feature will allow an end user to
estimate the ultrasonic signal strength and tracking geometry
quality under a Constellation. For more information on this
tool click on About.
Tracking Report Information is gathered about all PSEs. A history of when
stations become ‘lost’ and then reacquire is also recorded at
the bottom of the file. This report is helpful when a PSE
hardware failure is suspected. The Tracking report file can be
saved as a text file and e-mailed to InterSense technical
support for review. The Constellation must be retrieved and
Display turned on in order to record this data.
SoniStrip Fit Report Useful to estimate the overall accuracy in calibration of a
constellation file which uses SoniStrips. The positions and
distances between three SoniDiscs on one SoniStrip are
compared to SoniStrip manufacturing specifications.
Inaccuracies in the calibration of the SoniDiscs will affect the
overall accuracy of the IS-900 system.