User's Manual

Table Of Contents
InterSense Doc. No. 072-00105-0I07 Rev. 4.2
IS-900 User Guide Page 72 of 177
4.4.1. System Configuration Commands
Time Units The time stamp recorded is the time when the tracker data
was collected from the hardware. The time index is set to
zero when tracker is first turned on.
MT<> Sets the units for the data record time stamp to
milliseconds.
Mt<> Sets the units for the data record time stamp to
microseconds.
Default T
Set Current Time to Zero MZ<> This command sets current time index of the
tracker to zero.
Set Ethernet Communication Parameters
MEthIp{address}<> Sets System IP address.
Use dotted format like 192.168.1.1. If address is omitted,
the current address is returned, 31EI[address]<>. The IP
address takes effect immediately unless an address was
already set, in which case system settings must be saved
and the system must be restarted.
MEthTcpPort{port}<> Sets TCP communication port.
MEthUdp{state}<> Sets state of UDP broadcast.
1=enabled, 0=disabled
MEthUdpPort{port}<> Sets UDP broadcast port.
MEthSubnet{subnet}<> Sets network subnet.
MEthMode{mode}<> Sets network subnet.
2=DHCP, 1=manual, 0=disabled
MEthApply<> Apply Ethernet settings (settings must be
saved to make this permanent).
Default Ethernet communications settings:
UDP state OFF
UDP port 5001
TCP port 5005
Subnet 255.255.255.0
IP address None