Installation Sheet

INSTALLATION INSTRUCTIONS
Model # 72494
READ AND SAVE THESE INSTRUCTIONS
WAR NI N G! S H U T P O W E R O F F AT F U S E O R C I R C U I T B R E AK E R .
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
Notice:It is important to use proper chain pliers(not included)
To OPEN and CLOSE the chain included with this fixture.Do
not open them with other tools that may twist or stress the
chain links. It is important to use proper chain pliers like the
ones shown in the diagram.
BARE COPPER(GROUND)
Fig.2
FIXTURE
WIRES
RIBBED
BLACK
(HOT)
WIRES
HOUSE
GREEN OR
WHITE
WIRES
HOUSE
(GROUND)
COPPER
BARE
FIXTURE
WIRES
SMOOTH
WIRES
FIXTURE
GREEN OR
HOUSE
WIRES
HANGING THE FIXTURE (Fig.1)
1. Shut off the power at the fuse box or circuit breaker box
and remove the old fixture, including the mounting
hardware. Carefully unpack your new fixture and layout
All parts in a clear area. Take care not to lose any small
parts necessary for installation.
2. Thread nipple (D) into loop (I) until snug.
3. Thread other end of nipple (D) into the crossbar (A)
until snug and secure with l hex nut (F). Note the length
of nipple (D) into crossbar (A) may need to be adjusted.
Make sure" GND" facing outside.(E)
4. Attach the crossbar assembly to the ceiling outlet
box(C)(not included) with screws (B). “GND must face
out.(E)
5. Determine the desired hanging height and remove the
excess chain with pliers to avoid damaging the finish.
6. Open one end of the chain(J) and connect it to the
fixture loop (K) and close the link. Thread the wire
carefully through the chain links.
7. Place lock ring (H) followed by canopy (G) over the
chain and allow them to carefully rest on the fixture
body.
8. Open the other end of the chain(J) and attach it to
chain loop (I) and close the link.
9. Feed the wires through loop (I), and nipple (D).
CONNECTING THE WIRES (Fig.2)
10. Connect the electrical wires as shown in Fig. 2, making
sure that all wire connectors are secured. If your outlet
has a ground wire (green or bare copper), connect the
fixture’s ground wire to it. Otherwise, connect the
fixture’s ground wire directly to the crossbar using the
green screw(E) provided. Tuck the wire connections
neatly into the junction box.
FINISHING THE INSTALLATION (Fig. 1)
11. Raise the canopy (G) to the ceiling and secure with
lock ring (H).
12. At this point, install a 60W/E26/ST58 (not included) or
any Type A bulb in accordance with the fixture
specification. DO NOT EXCEED THE MAXIMUM WATTAGE
RATING!(NE PAS DEPASSER LA PUISSANCE NOMINALE
MAXIMALE!)
Your installation is now complete. Return power to the junction
box and test the fixture.
Note: Illustration (Fig. 1) on this manual is for installation
purposes only. It may or may not be identical to the fixture
purchased.
Fig. 1
“CAUTION-RISK OF FIRE CONSULT WITH A
QUALIFIED ELECTRICIAN TO ENSURE
CORRECT BRANCH CIRCUIT CONDUCTOR”
ATTENTION RISQUE D’INCENDIE, CONSULTER
UN ÉLECTRICIEN QUALIFIÉ POUR VOUS
ASSURER QUE LES CONDUCTEURS DE LA
DÉRIVATION SONT ADÉQUATS.
Notice:It is important to use proper chain pliers(not included)
To OPEN and CLOSE the chain included with this fixture.Do
not open them with other tools that may twist or stress the
chain links. It is important to use proper chain pliers like the
ones shown in the diagram.
SET A-012
-Cross Bar
-Ground Screw
-Mounting Screws(2)
Chain# HCH2072-68

Summary of content (1 pages)