Installation Sheet

INSTALLATION INSTRUCTIONS
Model # 72611-287G/72611-295G/72611-66G
READ AND SAVE THESE INSTRUCTIONS
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
-
PREPARING FOR INSTALLATION (Fig. 1)
1. Shut off power at the circuit breaker (avertissement!
couper le courant au niveau des fusibles ou du
disjoncteur) and remove the old fixture including the
mounting hardware.
2. Carefully unpack your new fixture and lay out all the
parts in a clear area. Take care not to misplace any
small parts necessary for installation.
3. Unscrew the cap nuts (H) and the rubber washers (G),
and separate the mounting plate (C) (part #: A-020)
from back plate (F), then attach the mounting plate(C)
to the outlet box (A) with the outlet box screws (D)
(size:8-32*1/2L)
Note: the side of mounting plate marked “GND” must
face out.
4. Adjust the two mounting screws (E) on mounting plate
(C) spaced the same distance apart as the holes on
back plate(F). Secure mounting screws (E) into
mounting plate (C) with the hex nuts provided. Note:
The length of mounting screws (E) into mounting plate
(C) may be adjusted if necessary.
CONNECTION THE WIRES (Fig. 2)
5. Connect the electrical wires as shown in Fig.2. making
sure that all wire connectors(B) are secured. If your
outlet box has a ground wire (green or bare copper),
connect the fixture’s ground wire to it. Otherwise,
connect the fixture’s ground wire directly to the circular
strap using the green screw
FINISHING THE INSTALLATION (Fig.1)
6.
Align back plate (F) onto mounting plate (C) and secure
with the rubber washers (G) and cap nuts (H).
7.
Install 60W / type A bulbs (bulbs not included) in
accordance with the fixture specification. —DO NOT
EXCEED THE MAXIMUM WATTAGE RATING!
(NE PAS DEPASSER LA PUISSANCE NOMINALE
MAXIMALE!)
8. To prevent moisture from entering the outlet box (A)
and causing a short, use clear silicone sealant to outline
the outside of fixture back plate (F) where it meets the
wall leaving a space at bottom to allow moisture a
means to escape. (Fig .3)
Your installation is now complete. Return power to the outlet
box and test the fixture.
IMPORTANT: FIXTURE SHOULD BE INSTALLED BY A
QUALIFIED ELECTRICIAN TO ENSURE PROPER WIRING AND
INSTALLATION.
Fig 3
Caulking
Back
p
late
BARE COPPER(GROUND)
Fig.2
FIXTURE
WIRES
WHITE
BLACK
(HOT)
WIRES
HOUSE
GREEN OR
WHITE
(NEUTRAL)
WIRES
HOUSE
(GROUND)
COPPER
BARE
FIXTURE
WIRES
BLACK
WIRES
FIXTURE
GREEN OR
HOUSE
WIRES
Fi
g
. 1
Part# A-020
Mounting Plate 1
Mounting screw (2)
Grounding screw(1)

Summary of content (1 pages)