Microinverter Instructions
Installing the BDM‐250 Micro inverter System involves several key steps:
1. Measuring service and installing the AC branch circuit junction box.
WARNING: ONLY USE ELECTRICAL SYSTEM COMPONENTS APPROVED FOR WET LOCATIONS.
2. Attaching the BDM‐250 Micro inverter to the racking.
3. Connecting the BDM‐250 Micro inverter wiring harnesses.
4. Grounding the system.
5. Completing the BDM‐250 Micro inverter installation map and connecting the PV modules.
The finished system should be similar as in the diagram. Detailed installation steps are listed in the following
section.
Step 1 - Install the AC Branch Circuit Junction Box
1. Measure service entrance conductors to confirm AC service at the site. Acceptable ranges are shown
in the table below:
BDM‐250‐240A & BDM‐250‐208A (North America)
240 Volt AC Single Phase
208 Volt AC Single Phase
L1(red) to L2(black) 211 to 264 Vac
L1(red)
toL2(black) 183 to 229 Vac
L1(red), L2(black) to
106 to 132 Vac
L1(red),
L2(black)
106 to 132 Vac
neutral(blue)
to
neutral(blue)
●BDM‐250‐AU (Australia and New Zealand)
L1(red)to
L2(black)
200 t
o
270 Vac
●BDM‐250‐EU (Europe)
L1(red) to L2(black) Refer to the grid code requirement of local authority
2. Mount the adapter plate at a suitable location on the PV racking system (typically at the end
of a row of modules).
3. Install an appropriate junction box with the adapter plate.