Instructions / Assembly

SP-1000
The Solar PaQ
Solar Panel + Inverter + Universal Roof Mount Racking
UPC: 861150002609
Microinverter Instructions
6. OPERATING INSTRUCTIONS
The BDM‐250 is powered on when sufficient DC voltage from the module is applied. The status LED
will start flashing after sufficient DC power is applied as an indication that the BDM‐250 is live.
Status: standby
The LED light is on by 2 second, and off by 2 seconds.
Status: producing power
The LED light is on by 1 second, and off by 1 second.
Error code
Error
Bit‐0 DC over voltage
Bit‐1 DC under voltage
Bit
‐2
hardware error
Bit‐3 Inverter over voltage
Bit
‐4
Frequency over
Bit‐5 Frequency under
Bit
‐6
AC voltage RMS over
Bit‐7 AC voltage RMS under
Bit
‐8
Peak AC voltage over
Bit
‐9
AC current RMS over
Bit‐10 Peak AC current over
Bit‐11 Temperature over
Bit‐12 ADC error
Bit
‐13
GFDI fault indicator
Bit‐14 Relay fault (BDM‐250‐AU/BDM‐250‐EU only)
Bit
‐15
PLC Communication Error