309560 04 GB RAMSES RAMSES 856 top2 OT Heating controller 8569132 Installation and operating guide OT Box RAMSES top2 OT – Standard box D GB E I F NL RAMSES 856 top2
Contents Proper use Proper use Disposal Safety advice Installation and dismantling Connection Terminal layout Description Start-up with RAMSES 850 top2 OT Set TSP parameters (Transparent Slave Parameters) Set heating curve of second heating circuit on controller Systems/Applications 1–5 System 1 System 2 System 3 System 4 System 5 – comfort box 2 2 3 3 4 5 6 7 8 8 9 10 11 12 13 14 Switch chimney sweep function on/off Operating hours counter Connect USB/GSM modem Error messages Technical data Service add
Safety advice Put on upper part of the OT-Box RAMSES top2 OT, click in and secure with bayonet socket. Afterwards optionally click in baffle or RAMSES 850 top2 OT in opening. WARNING Danger of death through electric shock or fire! Installation should only be carried out by a qualified electrician! Connect OT-Box RAMSES top2 to power supply. Dismantling Remove RAMSES 850 top2 OT or screen. Use a screwdriver to unlock upper part, remove and open device. If necessary take base from wall.
Connection WARNING Danger of death through electric shock! Must be installed by qualified electrician! Disconnect power source. Cover or shield any adjacent live components. Ensure device cannot be switched on! Check power supply is disconnected. Earth and bypass. 1,25 A T 1,25 A T Bus bar earthing conductor Connect all consuming equipment (pumps, etc.) and sensors. Connect RAMSES 850 top2 OT via OT interface. Connect mains power between (L) (N) (terminal 1 ).
Terminal layout GB Outputs – Heating circuit 1 pump as relay output 8 – Heating circuit 2 pump as relay output 7 – Burner as relay output 6 – Mixer closed (or 2nd burner stage) as relay output 5 – Mixer closed (or 2nd burner stage) as relay output 4 – Pump for domestic hot water feed as relay output 3 – Pump for domestic hot water circulation as relay output Inputs – Input fault 9 10 (see page 4) – OpenTherm-Slave (Connection RAMSES 850 top2 OT) – OpenTherm-Master (Connection of second OT-Box) 14 – Domes
Description USB connection 1 1 1 2 2 2 1 2 1 2 LED for operating state OpenTherm 2LED for pump 1 LED for pump 2 LED for burner (or error) LED for mixer open LED for mixer closed LED for domestic hot water (DHW) feed LED for domestic hot water (DHW) circulation Button for switching outputs (for test function without RAMSES 850 top2 OT) Button and LED for chimney sweep function 6
Start-up with RAMSES 850 top2 OT • The OT box RAMSES top2 can be adapted for the particular heating system (5 systems) by setting different applications. After connection, the messages follow in the display (see image). • The selection “Weather or room-dependent control” is made via the sensor connection. If an ambient temperature sensor is connected, it will be automatically detected and weather-dependent control will be carried out.
Set TSP parameters (Transparent Slave Parameters) 0: Domestic hot water circulation pump only runs when temperature-controlled 0–99: Domestic hot water circulation pump via ΔT on, Value is the maximum runtime in s 10 Pump protection time (0 .. 11 pm, default 12) 11 Pump protection duration in s (0…99, default 15, 0 = no pump protection) 12 ΔT for sequence control (5 ... 25, default 15) resolution 0.1 K 13 ΔT1 for pump switch heater 1 (5 ..
Systems/Applications 1–5 which are linked via the OpenTherm bus. RAMSES 850 top2 OT as well as both boxes are linked with one another via the OpenTherm bus. The centre box must be linked to the 0–10 V (terminal 15 - 15) input with a wire bridge. With the RAMSES 856 top2 OT an additional OT box (standard box 9070712) will be required for this system. • For the systems or applications 1-4 the OT-Box RAMSES top2 OT is required. The OpenTherm bus links RAMSES 850 top2 OT with the OT box RAMSES top2 OT.
System 1 System 1 consists of a maximum of: • Burner • Heating circuit without mixer • Heating circuit with mixer • Water storage tank • Domestic hot water circulation pump (Domestic hot water return pump) Mixer + 5 Burner Brenner External temperature sensor 19 Pump heating circuit 2 7 Feed temperature sensor 17 Fußboden Floor Domestic hot water temperature sensor 14 Heater Wärmeerzeuger Pump domestic hot water feed 3 Pump domestic hot water circulation 2 Domestic hot water tank Domestic hot wat
System 2 System 2 (not for AT-dependent control) consists of a maximum of: • Burner with 2 stages • Heating circuit without mixer • Water storage tank • Domestic hot water circulation pump (Domestic hot water return pump) Heating element Heizkörper External temperature sensor 19 Burner Brenner Stage 1 Stage 2 Stufe1 Stufe2 Fußboden Domestic hot water temperature sensor 16 Heater Wärmeerzeuger The individual functions are activated by connecting the appropriate sensor, i.e.
System 3 Heizkörper System 3 consists of: • Burner • Heating circuit without mixer • 2. Heater (e.g. solid fuel boiler) • Buffer storage • Water storage tank • Domestic hot water circulation pump (Domestic hot water return pump) The individual functions are activated by connecting the appropriate sensor, i.e. the domestic hot water program is only executed when the domestic hot water temperature sensor is connected.
System 4 System 4 consists of: • Burner • Heating circuit with mixer • 2. Heater (e.g. solid fuel boiler) • Buffer storage • Water storage tank • Domestic hot water circulation pump (Domestic hot water return pump) The individual functions are activated by connecting the appropriate sensor, i.e. the domestic hot water program is only executed when the domestic hot water temperature sensor is connected.
System 5 – comfort box System 5 consists of: • Burner • Heating circuit 1 with mixer • Heating circuit 2 with mixer • 2. Heater (e.g. solid fuel boiler) • Buffer storage • Water storage tank • Domestic hot water circulation pump (Domestic hot water return pump) The Comfort box consists of RAMSES 850 top2 OT and 2 standard boxes (centre box and end box). With it additional inputs/outputs are available for the connection of pumps, etc. Standard box (without RAMSES 850 top2 OT) can be obtained from Theben.
Centre box End box Power connection 1Input configuration • RAMSES 850 top2 OT 13 • End box OT 14 • Wire bridge 15 • Buffer tank temperature top 16 • Feed temperature heating circuit 2 17 • Temperature 2.
System 5 Comfort box with centre box and end box Sensor feed temperature 1 End box 17 Mixer + End box 5 External temperature sensor End box 19 Mixer – End box 4 Mixer + Centre box 5 Pump heating circuit 1 End box 8 Heizkörper Sensor feed temperature 2 Centre box 17 Mixer – Centre box 4 Pump heating circuit 2 End box 7 Boiler temperature sensor End box 16 Boiler pump 6 Centre box Domestic hot water temperature sensor, Centre box 16 Boiler temperature sensor Centre box 18 Burner Brenner Pump secon
2 Switch chimney sweep function on/off Connect USB/GSM modem Press button on the OT-Box RAMSES top2 OT x 1. The LED lights up. The chimney sweep function (burner + pump, for measurement of emissions by the chimney sweep) is on (full load). Press button again; the function is switched off. If not switched off manually the chimney sweeping function ends automatically after 30 mins. In the SETTINGS menu the additional sub-menu PIN CODE appears.
Error messages When you receive PIN:xxxx Set:xx,x via SMS, Replace the x with the correct PIN code/desired temperature. If an error occurs during the adjustment, error codes appear in the RAMSES 850 top2 OT display. Error codes 20-28 originate with a sensor error. 2. Weather-dependent control With the weather-dependent control, you can select the operating mode by SMS. Errorcode 11 20 21 22 23 24 25 26 27 28 29 30 31 Send the PIN number and operating mode via SMS to the USB/GSM modem: e.g.
Technical data • Mode of operation: Type 1 B in accordance with EN 60730-1 • Pollution degree: 2 • Rated impulse withstand voltage: 4 kV • Operating voltage: 230 V~, +10/–15 % • Frequency: 50 Hz • Power consumption: typically 2.7 VA • Standby: typically 1.1 W • Switch load: Relay: 5 x max.
Service address/Hotline Service address Theben AG Hohenbergstr. 32 72401 Haigerloch GERMANY Telephone +49 7474 692 0 Fax +49 7474 692-150 Hotline Telephone +49 7474 692 -369 Fax +49 7474 692-207 hotline@theben.de Addresses, telephone numbers etc. www.theben.