SDS

_____________________________________________________________________________________________
1118844 - ThermaCELL C15 Cartridge
Revision Date 11-Jul-2017
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Guidelines
The following ingredients are the only ingredients of the product above the cut-off level (or
level that contributes to the hazard classification of the mixture) which have an exposure
limit applicable in the region for which this safety data sheet is intended or other
recommended limit. At this time, the other relevant constituents have no known exposure
limits from the sources listed here
Chemical name ACGIH TLV OSHA PEL NIOSH IDLH
L.P.G. (liquified petroleum
gas)
68476-85-7
: See Appendix F: Minimal Oxygen
Content
TWA: 1000 ppm
TWA: 1800 mg/m
3
(vacated) TWA: 1000 ppm
(vacated) TWA: 1800 mg/m
3
IDLH: 2000 ppm
TWA: 1000 ppm
TWA: 1800 mg/m
3
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value OSHA PEL: Occupational Safety and Health
Administration - Permissible Exposure Limits NIOSH IDLH Immediately Dangerous to Life or Health
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992) See section 15 for national exposure control parameters
Appropriate engineering controls
Engineering Measures
Showers
Eyewash stations
Ventilation systems
Individual protection measures, such as personal protective equipment
Eye/face protection
Tight sealing safety goggles.
Skin and body protection
Wear protective gloves and protective clothing. Long sleeved clothing. Chemical resistant
apron. Impervious gloves. Antistatic boots.
Respiratory protection
No protective equipment is needed under normal use conditions. If exposure limits are
exceeded or irritation is experienced, ventilation and evacuation may be required.
7. HANDLING AND STORAGE
Precautions for safe handling
Handling
Handle in accordance with good industrial hygiene and safety practice. Avoid breathing
vapors or mists. Avoid contact with eyes. Keep away from open flames, hot surfaces and
sources of ignition. Contents under pressure. Do not puncture or incinerate cans.
Conditions for safe storage, including any incompatibilities
Storage
Store locked up. Keep containers tightly closed in a dry, cool and well-ventilated place.
Keep away from heat, sparks, flame and other sources of ignition (i.e., pilot lights, electric
motors and static electricity). Keep in properly labeled containers. Do not store near
combustible materials. Keep in an area equipped with sprinklers. Store in accordance with
the particular national regulations. Store in accordance with local regulations.
Incompatible Products
None known based on information supplied.
_____________________________________________________________________________________________
Page 5 / 11