Installation Guide

Table Of Contents
en-us Prepare installation space
6
¡ If the thickness of the countertop into which the cooktop
is installed does not comply with the specifications, rein-
force the worktop using a fire- and water-resistant mate-
rial until it reaches the minimum thickness. Otherwise,
sufficient stability cannot be assured.
¡ The countertop into which the cooktop is installed
should withstand loads of approx. 133lbs (60kg).
¡ Confirm the cooktop is level only after it has been in-
stalled.
3.1 Cutout dimensions for 30" cooktops
Refer to these measurements for the models stated here.
¡ CIT304YB
¡ CIT304YM
3.2 Cutout dimensions for 36" cooktops
Refer to these measurements for the models stated here.
¡ CIT365YB
¡ CIT367YG
¡ CIT367YGS
¡ CIT367YM
¡ CIT367YMS
3.3 Cabinet ventilation requirements
To assure that the appliance works correctly, the cooktop
MUST be sufficiently ventilated.
The ventilation in the lower section of the appliance re-
quires a sufficient supply of fresh air. Ensure that the cabi-
net is designed in a way that supports sufficient ventila-
tion. The following requirements must be fulfilled:
Notes
¡ A minimum clearance between the rear of the cabinet
and the kitchen wall, and between the surface of the
countertop and the upper area of the drawer.