Installation Guide

Installation Instructions English | 15 |
4. Slide the hood back against the wall. Tighten the
mounting screws. Be sure the screw heads are in the
narrow neck of the keyhole slot.
B
A
5. Drive 2 pieces of the selected screws in the lower
security screws location (see the image above).
6. Connect Ductwork to hood.
Cabinet Installation
Turn power OFF at the service panel. Lock service panel
to prevent power from being turned ON.
Cabinet cutouts
1. Use the diagram or the hood as a template and mark
the locations on the cabinet for ductwork, electrical
wiring and keyhole screw slots.
Center
Line
A
A
C
D
E
F
I
G
H
A
B
A
Front face
of the cabinet
Bottom face
of the cabinet
Wall
A
5
4
16” (13.3 cm)
F
3
7
16” (8.7 cm)
B
3
4” (1.9 cm)
G
1
1
2” (4 cm)
C
6
16” (1 cm)
H
1” (2.54 cm)
D
7
1
16” (18 cm)
I
3
16” (.5 cm)
E
2
9
16” (6.5 cm)
For recessed bottom cabinet only
If the cabinets have front, side or back trim, make 2 wood
shims the width of the trim and attach them to the cabinet
bottom recess on both sides.
NOTE: Your cabinet must be able to support at least 88 lb
(40 kg).
Drive a mounting screw (from the hardware package)
partway into each center of the narrow neck of the
keyhole slots marked on the cabinet bottom or the
wall’s support frame.
Install 4 - 4 x 8 mm mounting screws on the mountings
screws location (see the image). Leave a
1
4’ (6.4 mm)
gap between the wall and the back of the screw head
to slide range hood into place.
1
/
4
"
(6.4 mm)
Fix the wiring conduit of the hood.
Slide the hood back against the cabinet. Tighten the
mounting screws. Be sure the screw heads are in the
narrow neck of the keyhole slot.
A