installation instructions

Page. 15
Changing the broil orifice, on
GAS ranges only (PRG models)
9 CAUTION
After the replacement of the broiler orifice, and
before reassembly of the back panel and backguard to
the range, perform a brief gas leakage check of the
orifice and associated fittings, per the “Check for Gas
Leaks” section of these instructions.
Removing the backguard assembly
1. Move the range out of its installed position to gain full
access to the rear panel of the backguard assembly
and to the broil burners' orifices.
2. Use a T-20 torx screwdriver to remove the screws from
the front of the backguard assembly.
3. Use a T-20 torx screwdriver to remove the screws from
the back rear panel of the backguard assembly.
4. Carefully lift the backguard assembly from the range.
Changing the broil burner orifice
NOTE: This procedure applies to both the main oven broil
burner and, when applicable, to the auxiliary oven broil
burner.
1. Remove broil orifice using a 7/16'' box end wrench,
while restraining the elbow fitting from rotation using
a small adjustable wrench.
Model 606 with griddle
(1) 105 (3) 105
(5)
(6) 105
(2) 126 (4) 115 (7) 115
33
44
66
77
11
22
55