Installation Instructions

Installation Instructions English 14
Important Installation Information
The anti-tip bracket may be attached to a solid wood
surface having a minimum wall thickness of ¾''
(19 mm).
The thickness of the wall or floor may require use of
longer screws, available at your local hardware store.
In all cases, at least two (2) of the bracket mounting
screws must be fastened to solid wood surface.
Use appropriate anchors when fastening the mounting
bracket to any material other than hard-wood or metal.
Hole location preparation
For walls, wall studs, or floors composed of solid wood
or metal, drill 1/8'' (3 mm) pilot holes.
For walls or floors composed of drywall, sheet-rock or
other soft materials, drill 3/16'' (5 mm) holes to a
minimum depth of 1¾'' (45 mm), then tap plastic
anchors into each of the holes using a hammer.
For walls or floors composed of concrete or concrete
block, drill 3/16'' (5 mm) holes to a minimum depth of
1¾'' (45 mm), then tap concrete anchors into each of
the holes using a hammer.
For walls or floors having ceramic tile covering, drill
3/16'' (5 mm) holes through the tile only, then drill into
the material behind the tile as indicated immediately
above.
Mounting Anti-Tip Bracket
The floor mounted bracket shall be installed as follows:
1. Place bracket on floor in position shown in Figure 8.
Bracket may be used in either corner of the
installation area.
2. Secure to floor and wall stud using the (4) 1½'' (38 mm)
Phillips head screws provided.
3. Later, when the unit is installed, the adjustable leg will
slide under the bracket, as shown in Figure 8.
4. If the range is moved to a new location, the Anti-Tip
Device must be removed and reinstalled.
STEP 5: Gas Requirements
and Hookup
Verify the type of gas being used at the installation site.
The appliance is shipped from the factory for use with
natural gas. It must be converted for use with propane.
A qualified technician or installer must do the
conversion. Make certain the range matches the type of
gas available at this location.
This appliance has been CSA certified for safe operation
up to an altitude of 2,000 ft (610 m) elevation above sea
level.
High Altitude — For altitudes above 2,000 feet (610 m)
elevation above sea level, adjustments can be made with
the High Altitude Packet included with the unit. If flame
performance is satisfactory, the contents in this packet will
not be required. It is required that a Certified Professional
make the high altitude adjustments during installation.
Propane (LP) Gas Appliances – The appliance must first
be converted for use with Propane (LP) Gas before it can
be converted for use at high altitude. A Propane (LP)
Conversion Kit (PALPKITHN) is required and available for
purchase from Thermador Customer Service.
SERVICE
PART NO.
QTY DESCRIPTION
00415078 4 Screw, Phillips, #10 x 1½''
00647936 1
Anti-Tip Bracket, Floor-
Mounted
Hardware provided is for mounting through standard
thickness wood studs. Installers are responsible to
provide hardware for other types of mounting situations.
Range Side Distance of X
30'' Left or Right 2¼'' (57 mm)
36'' Left or Right 2ǫ'' (67 mm)
48'' Left or Right 2½'' (64 mm)
Figure 8: Placement of Anti-Tip Bracket
C
L
C
L
x
x
x
x