Installation instructions
Planning information
9 CAUTION
To prevent possible damage to cabinets and cabinet
finishes, use only materials and finishes that will not
discolor or divide into layers. Materials should be able
to withstand temperatures up to 194 °F (90 °C). Heat
and moisture resistant adhesive must be used if the
product is to be installed in laminated cabinetry.
Check with the manufacturer to ensure materials meet
these requirements.
Before using your appliance, be sure to read this manual.
Pay special attention to the “Important safety
instructions” located at the beginning of the manual.
Tools needed
7/16'' box end wrench or ratchet
3/16'' (4.76 mm) drill bit
Hand or electric drill
1/8'' (3.17 mm) drill bit
12'' Adjustable wrench
T-20 screwdriver
T-30 screwdriver
Tape measure
Furniture dolly or air sled
Phillips screwdriver
Level
Marking instrument
Protective gloves
Safety glasses
Items not included
Drywall / Concrete Anchors
•Rope/Twine
2 – NPT Flare Adapters
Pipe Compound / Tape
¾'' (19 mm) Flex Line
IMPORTANT: There is a possibility to discolor the back
wall under certain cooking conditions.
Ventilation requirements
9 WARNING
This appliance should not be installed with a
ventilation system that directs air in a downward
direction toward the range. This type of ventilation
system may cause ignition and combustion problems
with the appliance resulting in personal injury,
property damage, or unintended operation.
Ventilating systems that direct the air upwards do not
have any restriction.
Refer to the “Ventilation planning guide” for approved
ventilation combinations.
It is strongly recommended that this appliance be installed
in conjunction with a Thermador
®
vent hood. Due to the
high heat capability of this unit, particular attention should
be paid to the hood and duct work installation to assure it
meets local building codes.
Downdraft ventilation should not be used. The
“Ventilation planning guide” indicates the ventilation
hood options and blower capacity guidelines that are
recommended for use.
Due to the high heat of the rangetop burners, installing a
microwave oven with a ventilation system over the
rangetop is not recommended.
Ventilation hoods and blowers are designed for use with
single wall ducting. However, some local building codes or
inspectors may require double wall ducting. Consult local
building codes and/or local agencies before starting to
assure that hood and duct installation will meet local
requirements.
NOTICE: Most range hoods contain combustible
components which must be considered when planning the
installation.