LP Gas Conversion

Installation Instructions English | 5 |
3. Re-install conversion cap, configured for LP gas, back
into top of the regulator.
Replace the Burner Orifices
1. Use a 7 mm or a 9/32'' socket with 1/4'' nut driver to
reach down through the jet holders and remove the
Natural Gas orifice from the burner’s jet holder.
2. Locate the proper LP surface burner orifices included
with the kit.
Orifice locations for 36'' models with 4 burners
Orifice locations for 36'' and 48'' models with 6 burners
Orifice locations for 60'' models with 6 burners
3. Install the orifices in their correct location according to
the tables above.
All of the replacement orifices in the conversion kit
have straight threads (not pipe threads) and do not
require thread sealing compound.
4. Perform a gas leakage test of each orifice and
associated supply tube fittings. See “Check for Gas
Leaks” on page 8.
Leak-checking should occur after the orifice
conversion is complete, and before the burner is
reassembled and tested.
Orifices are stamped with the
orifice diameter size on the side.
Brass Cap
Sealing Washer
Plunger
Regulator Body
Burner Orifice Size BTU Rate LP
Left front (XLO) 1.15 15,000
Left rear (XLO) 1.15 15,000
Right front (XLO) 1.25 18,000
Right rear (XLO) 1.15 15,000
Burner Orifice Size BTU Rate LP
Left front (XLO) 1.15 15,000
Left rear (XLO) 1.15 15,000
Center front 1.15 15,000
Center rear 1.15 15,000
Right front (XLO) 1.25 18,000
Right rear (XLO) 1.15 15,000
Burner Orifice Size BTU Rate LP
Left front (XLO) 1.25 18,000
Left rear (XLO) #62 11,000
Center front 1.15 15,000
Center rear #62 11,000
Right front (XLO) 1.15 15,000
Right rear (XLO) #64 9,100