Installation Instructions

Table Of Contents
Page. 24
3. Repeat the ignition and flame test for each rangetop
burner.
The burners that feature XLO
®
, cause the flame to cycle
on and off when the knob is set to the XLO function. This
is normal operation.
When flame is properly adjusted:
There should be a flame at each burner port.
There should be no air gap between the flame
and burner port.
Call Thermador service if:
Any of the burners do not light.
Any of the burners continue to burn yellow.
Flame characteristics
Yellow flames:
Further Adjustment is
required.
Yellow tips on outer cones:
Normal for LP Gas
Soft blue flames:
Normal for Natural Gas
If the flame is completely or mostly yellow, verify that
the regulator is set for the correct fuel. After
adjustment, retest.
Some orange-colored streaking is normal during the
initial start-up.
Allow unit to operate 4-5 minutes and re-evaluate
before making adjustments.