Installation guide

5. Preparing the installation cavity
[_2 anti tip brackets are required for each appliance
or appliance combination (Side by Side).
C3 Specify the attachment points of the
anti tip brackets.
Specify the detailed dimensions according to the
section on "Installation dimensions" starting on
page 8.
Assure that there are no electrical wires or plumbing
in the area which the screws could penetrate risk of
injury and damage!
iiiiiiiiiiiiiiiiii
C3 If the installation cavity is deeper than the appliance,
place a solid wooden beam behind the
anti tip brackets and attach securely to the base or
the watt.
The length of the wooden beam is equal to the
width of the installation cavity!
If possible, always screw the wooden beam to
existing studs on the rear panel of the cavity.
In some installations the sub flooring or finished floor
may necessitate angling the wood screws used to
fasten the anti tip brackets to the back walt.
[_ Important information for secure attachment of the
anti tip brackets:
The supplied set contains fastening screws for
various applications. Select the fastening screws
according to the local conditions.
If the supplied fastening screws do not permit
secure attachment of the anti tip brackets and
therefore the appliance, another method must
be used to attach the anti tip brackets securely.
Wood floor application
Use the (5 x 60 mm) and (4 x 15 mm) wooden screws
provided.
C3 Drill pilot holes:
1/8" (3 mm) for the (5 x 60 mm) wooden screws
5/64" (2 mm) for the (4 x 15 mm) wooden screws
Being certain the screws penetrate through
the flooring and into the watt plate a minimum
of 3/4" (19 ram).
C3 Attach the anti tip bracket completely. Be sure
screws hold tight.
Concrete floor applications
Always wear safety glasses and other necessary
protective devices or apparel when installing or
working with anchors risk of injury!
Not recommended for use in light weight masonry
material such as block or brick.
Not recommended for use in new concrete which has
not had time to cure.
Do not use core drills to drill holes for this anchor.
Use concrete anchor M8 and M8 stew. Additional use
the (5x60 mm) and (4x15 mm) wooden screws
provided.
C3 Drill a 10 mm diameter hole any depth exceeding
the minimum embedment. Use the provided drill.
C3 Clean hole or continue drilling additional depth.
18