36-INCH DOWNDRAFT VENTILATION
MASTERPIECE
®
SERIES
FLEXIBLE BLOWER INSTALLATION – FRONT EXHAUST WITH FLEXIBLE BLOWER BELOW FLOOR LINE EXAMPLE
APPLICATION
- Front downward application with space under oor line for ductwork*
- Elbow and ductwork are not included
Page 15
A - Installation using flexible blower
attached to downdraft
FRONT
PANEL
FLEX
BLOWER
If blower
discharge is
down,
electrical
panel must be
relocated.
(Purchase Model VTD600P Flexible Blower separately.)
1. Remove hex nuts to remove front panel cover.
2.
3. If blower discharge is down, remove (4) #8-32 hex nuts and
4. Place blower over studs around front panel opening.
5. Tighten hex nuts to secure blower in place.
Based on blower and ducting option selected,
go to the relevent section:
A - Installation using flexible blower
attached to downdraft
B - Installation using flexible or remote
blower - mounted in a remote location -
ducting through front panel opening
C - Installation using flexible or remote
blower - mounted in a remote location -
ducting through left, right or rear
BLOWER
SUPPORT LEGS
(4) BOLTS
5.
this time.
B - Installation using inline or remote
blowers - with ducting through front
panel opening
CAUTION
alone for support. It may be necessary to add extra support for
FRONT
PANEL
6", 8", OR 10” (152MM, 203MM,
OR 254MM) ROUND
REMOTE ROUGH-IN
PLATE (Purchase Separately)
If blower
discharge is
down,
electrical
panel must be
relocated.
1. Remove hex nuts to remove front panel cover.
2. If blower discharge is down, remove (4) #8-32 hex nuts and
3. Place 6”, 8”, or 10” (152mm, 203mm, or 254mm) round rough-in
plate (purchase separately) over studs around front panel opening.
4.
Tighten hex nuts to secure remote discharge plate in place.
INST A LLA TION
* For front downward ducting applications, electrical panel must be remotely mounted. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel
to downdraft. Refer to installation manual.
REQUIRED BLOWER
VTD600P – 600 CFM
600 CFM exible blower
can be installed as an
integrated or inline blower
10
3
/
8
"
(264 mm)
12
3
/
4
"
(324 mm)
12
3
/
4
"
(324 mm)
7
3
/
8
"
(187 mm)
11
5
/
8
"
(295 mm)
5
1
/
4
"
(133 mm)
5
1
/
8
"
(130 mm)
11
5
/
8
"
(295 mm)
5"
(127 mm)
measurements in inches (mm)
10
3
/
8
"
(264 mm)
12
3
/
4
"
(324 mm)
12
3
/
4
"
(324 mm)
7
3
/
8
"
11
5
/
8
"
5
1
/
4
"
(133 mm)
5
1
/
8
"
(130 mm)
11
5
/
8
"
(295 mm)
5"
(127 mm)
measurements in inches (mm)
OPTIONAL ACCESSORIES
REQUIRED ACCESSORIES
EXTNCE5
This cable extends 5 ft. to move the electrical panel
out of the way to offer full installation exibility in
any ducting scenario while installing the downdraft.
Ability to connect two cables together to make a
10 ft. cable.
CVTFRONT8
8" round front plate allows
for front downward venting.
Use with VTD600P blower
as an inline installation, and
ducting with 8" round duct
connections.
DOWNDRAFT GAS
COOKTOP SEAL TRIM
KIT UCV36ST
Includes trim, seal, metal
grill, and fasteners.
Required for installations
with 36" gas cooktops.