Specifications

9 / 19
Page 11 of 13
UCVM36XS
36-INCH DOWNDRAFT VENTILATION
MASTERPIECE
®
SERIES
APPLICATION
- Rear or downward exhaust options to preserve precious kitchen storage space or if
ducting is more convenient for these congurations*
- Requires at least 18" of clearance to t the blower and transition
- Blower must be accessible for maintenance
- Elbow and ductwork are not included
FLEXIBLE BLOWER INSTALLATION – REAR OR DOWNWARD EXHAUST EXAMPLE
Rear Exhaust
Downward Exhaust
REQUIRED ACCESSORYREQUIRED BLOWER
VTD600P – 600 CFM
600 CFM exible blower can
be installed as an integrated
or inline blower
10
3
/
8
"
(264 mm)
12
3
/
4
"
(324 mm)
12
3
/
4
"
(324 mm)
7
3
/
8
"
(187 mm)
11
5
/
8
"
(295 mm)
5
1
/
4
"
(133 mm)
5
1
/
8
"
(130 mm)
11
5
/
8
"
(295 mm)
5"
(127 mm)
measurements in inches (mm)
10
3
/
8
"
(264 mm)
12
3
/
4
"
(324 mm)
12
3
/
4
"
(324 mm)
7
3
/
8
"
(187 mm)
11
5
/
8
"
(295 mm)
5
1
/
4
"
(133 mm)
5
1
/
8
"
(130 mm)
11
5
/
8
"
(295 mm)
5"
(127 mm)
measurements in inches (mm)
CVTSIDE8
8" round transition allows for rear or
downward venting. Use with VTD600P
blower as an inline installation, and ducting
with 8" round duct connections.
* For only front downward ducting applications, electrical panel must be remotely mounted. Electrical panel
can still be remotely mounted in other exhaust configurations if desired. Optional 5' extension cable EXTNCE5
accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual.
NOTE: Some applications may require deeper cabinets. Side and rear exhaust require at least 18" of clearance to
fit the blower and/or ductwork. Refer to installation manual.
OPTIONAL ACCESSORIES
EXTNCE5
This cable extends 5 ft. to move the electrical panel out of the way to
offer full installation exibility in any ducting scenario while installing
the downdraft. Ability to connect two cables together to make a
10 ft. cable.
REPLACEMENT CHARCOAL FILTER
UCVFILTER
Includes 1 replacement charcoal lter for
UCVRECIRC recirculation kit
DOWNDRAFT GAS COOKTOP SEAL
TRIM KIT UCV36ST
Includes trim, seal, metal grill, and fasteners.
Required for installations with 36" gas cooktops.
RECIRCULATION KIT
UCVRECIRC
Includes 1 charcoal lter and 1 metal grill
vent plate (blower sold separately). Use
with induction/electric cooktops only.