spec sheet

03 / 18
Page 10 of 12
UCVP36RS
36-INCH DELUXE DOWNDRAFT VENTILATION
MASTERPIECE
®
SERIES
APPLICATION
- Rear, left or right side exhaust options to preserve precious kitchen storage space or if
ducting is more convenient for these congurations*
- Requires at least 18" of clearance to t the blower and transition
- Blower must be accessible for maintenance
- Elbow and ductwork are not included
FLEXIBLE BLOWER INSTALLATION – REAR, LEFT OR RIGHT SIDE EXHAUST EXAMPLE
Rear Exhaust
Left Side Exhaust
Right Side Exhaust
* For only front downward ducting applications, electrical panel must
be remotely mounted. Electrical panel can still be remotely mounted
in other exhaust configurations if desired. Optional 5' extension cable
EXTNCE5 accessory is available to connect remotely placed electrical
panel to downdraft. Refer to installation manual.
NOTE: Some applications may require deeper cabinets. Side and
rear exhaust require at least 18" of clearance to fit the blower and/or
ductwork. Refer to installation manual.
REQUIRED ACCESSORYREQUIRED BLOWER
VTD600P – 600 CFM
600 CFM exible blower can
be installed as an integrated
or inline blower
10
3
/
8
"
(264 mm)
12
3
/
4
"
(324 mm)
12
3
/
4
"
(324 mm)
7
3
/
8
"
(187 mm)
11
5
/
8
"
(295 mm)
5
1
/
4
"
(133 mm)
5
1
/
8
"
(130 mm)
11
5
/
8
"
(295 mm)
5"
(127 mm)
measurements in inches (mm)
10
3
/
8
"
(264 mm)
12
3
/
4
"
(324 mm)
12
3
/
4
"
(324 mm)
7
3
/
8
"
(187 mm)
11
5
/
8
"
(295 mm)
5
1
/
4
"
(133 mm)
5
1
/
8
"
(130 mm)
11
5
/
8
"
(295 mm)
5"
(127 mm)
measurements in inches (mm)
OPTIONAL ACCESSORIES
EXTNCE5
Extends electrical panel cable 5-ft. to connect remotely located
electrical panel to downdraft. Ability to connect two cables together
to make a 10-foot cable.
REPLACEMENT CHARCOAL FILTER UCVFILTER
Includes 1 replacement charcoal lter for UCVRECIRC recirculation kit
DOWNDRAFT GAS COOKTOP SEAL TRIM KIT UCV36ST
Includes trim, seal, metal grill, and fasteners. Required for installations
with 36" gas cooktops.
CVTSIDE8
8" round transition allows for left, right, or
rear venting. Use with VTD600P blower as
an inline installation, and ducting with 8"
round duct connections.
RECIRCULATION KIT
UCVRECIRC
Includes 1 charcoal lter and 1 metal grill
vent plate (blower sold separately). Use
with induction/electric cooktops only