Installation Guide

Page 20
INSTALLATION
Install electrical wiring
CAUTION: Installation work and electrical wiring must be done
by quali ed person(s) in accordance with all applicable codes,
regulations, and standards, including  re-rated construction.
CAUTION: Do not use an extension cord. If the product power
cord is too short, have a quali ed electrician install a three slot
receptacle.
1. Install a standard wiring box, with 3-pronged receptacle, within reach
of the downdraft’s power cord.
2. Remove electrical panel wiring box cover. Secure blower power cable
to electrical panel wiring box with U.L. approved strain relief.
Based on blower selected, go to the relevent
section:
A - Flex blower wiring
B - Remote blower wiring
A - Flex blower wiring
3. Connect exible blower wires to wires in electrical panel wiring box
as shown. Cap off BLUE wire (LOW 1).
4. Replace wiring box cover.
CAUTION: Installation work and electrical wiring must be done
by quali ed person(s) in accordance with all applicable codes and
standards, including  re-rated construction.
FLEXIBLE
BLOWER
M
ELECTRICAL PANEL
WIRING
BOX
BLACK (HIGH 4)
WHITE (NEUTRAL)
GRAY (MED 2)
GROUND SCREW
ORANGE (MED-HIGH 3)
BLACK
WHITE
BLUE (CAP OFF)
RED
ORANGE
GREEN
BLUE (CAP OFF)
From exterior or
in-line blower
B - Remote blower wiring
REMOTE
BLOWER
M
ELECTRICAL PANEL
WIRING
BOX
BLACK (HIGH 4)
WHITE (NEUTRAL)
BLUE (LOW 1, CAP OFF)
GRAY (MED 2)
GROUND SCREW
ORANGE (MED-HIGH 3)
14/4 ROMEX
OR CONDUIT
Note: Some blowers may come with plugs or connectors, these
should be removed and the 14/4 ROMEX or Conduit wiring should be
connected in an approved junction box. As an alternative, the BSH 25'
Extension Cable Kit (EXTNCB25W) and the Extension Cable Connection
Kit (EXTNSET4) can be used in place of the ROMEX or conduit wiring.
Please follow all required and recommended wiring instructions in this
manual and the extension cable kits.
5. Connect power wires to wires in electrical panel wiring box as shown.
Cap off Low (Speed 1) wire.
6. Replace wiring box cover.
CAUTION: Installation work and electrical wiring must be done
by quali ed person(s) in accordance with all applicable codes,
regulations, and standards, including  re-rated construction.
3. The following exterior or inline blowers can be used:
VTR630P - 600 cfm (17 m
3
/min) Remote Blower
VTI610P - 600 cfm (17 m
3
/min) Inline Blower
120 VAC • 60 Hz • 5.0 A (max.)
4. Install a standard wiring box, with 3-pronged receptacle, within reach
of the downdraft’s power cord.