25
NUMBER MAXIMUM OIL FLOW MINIMUM OPERATING MOTOR (IN3/REV)
MODEL OF FANS FAN SPEED REQUIRED PER FAN (GPM) PRESSURE (PSI) DISPLACEMENT
AOC - 19 thru AOC - 33 1
AOC - 37 thru AOC - 57
2
1725 RPM
1.6 300 .22
AOC - 70 3.4 500 .45
Dimensions
AOC-37 thru
AOC-70
#20 1.25
#24 1.50
1.12
1.06
8.37
8.31
AOC-54 42.00 43.3830.50 33.28 27.25 39.50 4.89 6.30 43.75 154
AOC-19 16.50 18.1613.62 16.00 10.31 15.00
14.75 30
AOC-37 39.00 40.3818.50 21.38 15.25
4.62 5.97 40.50 95
36.50
AOC-50 41.00 42.3822.50 25.38 19.25
4.68 6.03 42.50 120
38.50
AOC-57 48.00 49.3836.50 39.38
6.68 8.15 49.75 190
32.75 45.50
AOC-70 51.00
#32 2.00
8.44 9.91 52.75 1.62 12.12 304
34.0052.38 48.5017.79 24.6238.38 41.25
AOC-22 22.00 23.6615.62 18.00
18.69 33
12.31 20.50
10.40
11.58
7.92
#12 .75 4.12
3.05 2.61
1.87 12.37
5.00
6.50
9.00
8.18
14.06
10.84
14.93
15.08
AOC-24 24.75 26.4119.62 22.00 16.31 23.25
21.44 46
9.69
AOC-33 30.25 31.9125.62 28.00 22.31 28.75
#16 1.00
4.34 26.97 65
9.31
NPT &
BSPP
SAE
NPT &
BSPP
SAE
MODEL
BYPASS
NO
BYPASS
WITH
BYPASS
NO
BYPASS
WITH
HYD DC
MOTOR MOTOR
A B C
D E
F G
H J M P
Weight
LBS.
AOC-19 thru
AOC-33
AOC - 19 THROUGH AOC - 33
AOC - 37 THROUGH AOC - 70
J
#8 SAE
"IN"
#8 SAE
"OUT"
AIR FLOW
AIR FLOW
TEMP. SENSOR
F ( 2 PLACES)
* IN or OUT
(OPTIONAL)
AIR
FILTER
AIR
FILTER
2.06
B
C C
G G
J
M
P
.41 X 1.19 SLOT
.41 X 1.19 SLOT
J
M
P
E
H
A
D
#8 SAE
"IN"
#8 SAE
"OUT"
1/2 NPT
FOR OPTIONAL
TEMP. SENSOR
F (2 PLACES)
AIR
FILTER
AIR
FILTER
SERVICEABLE
BYPASS VALVE
30 OR 60 PSI
3/8 NPT
DRAIN
.53 DIA HOLE
2 EACH BRKT
AIR FLOW
2.06
C
G
C
G
M
P
.53 DIA HOLE
2 EACH BRKT
AIR FLOW
J
M
P
B
E
H
A
D
"OUT"
"IN"
1/2 NPT
FOR OPTIONAL
HYDRAULIC MOTOR 12 or 24 VOLT DC MOTOR
HYDRAULIC MOTOR 12 or 24 VOLT DC MOTOR
Unit shown with optional Bypass Valve
Hydraulic Motor 12 or 24 Volt DC Motor
AOC - 19 THROUGH AOC - 33
AOC - 37 THROUGH AOC - 70
J
#8 SAE
"IN"
#8 SAE
"OUT"
AIR FLOW
AIR FLOW
TEMP. SENSOR
F ( 2 PLACES)
* IN or OUT
(OPTIONAL)
AIR
FILTER
AIR
FILTER
2.06
B
C C
G G
J
M
P
.41 X 1.19 SLOT
.41 X 1.19 SLOT
J
M
P
E
H
A
D
#8 SAE
"IN"
#8 SAE
"OUT"
1/2 NPT
FOR OPTIONAL
TEMP. SENSOR
F (2 PLACES)
AIR
FILTER
AIR
FILTER
SERVICEABLE
BYPASS VALVE
30 OR 60 PSI
3/8 NPT
DRAIN
.53 DIA HOLE
2 EACH BRKT
AIR FLOW
2.06
C
G
C
G
M
P
.53 DIA HOLE
2 EACH BRKT
AIR FLOW
J
M
P
B
E
H
A
D
"OUT"
"IN"
1/2 NPT
FOR OPTIONAL
HYDRAULIC MOTOR 12 or 24 VOLT DC MOTOR
HYDRAULIC MOTOR 12 or 24 VOLT DC MOTOR
Unit shown with optional Bypass Valve
Hydraulic Motor
12 or 24 Volt DC Motor
Unit shown with optional Bypass Valve
Notes: Maximum pressure is 2000 PSI. Stated Minimum Operating Pressure is at Inlet Port of Motor. 1000 PSI Allowable Back Pressure.
All dimensions in inches. We reserve the right to make reasonable design changes without notice. *Inlet and outlet oil ports reversible if relief bypass option is not used.
Hydraulic motor data
Speciļ¬cations
12 and 24 volt DC motor data
NUMBER FULL LOAD AMPS PER MOTOR HORSEPOWER FAN FAN
MODEL OF FANS 12 VOLT 24 VOLT PER MOTOR SPEED DIAMETER (INCHES)
AOC - 19 10
AOC - 22 1
12.5 6.3 1/5
12
AOC - 24, 33
1800 RPM
14
AOC - 37 12
AOC - 50, 54, 57 2 14
AOC - 70 80 39 1 20