Digital Shower Package Installation Manual For Tutorials and Troubleshooting visit www.thermasol.
SignaTouch Control Installation Manual For Tutorials and Troubleshooting visit www.thermasol.
Digital Shower Package 1 Important Information before You Install The SignaTouch Control must be installed inside the shower. The ThermaTouch control will only function on the current TFX, SSA and PRO Series generators. The control should be installed 60" from the floor of the shower and away from the steamhead. The steamhead should be installed 24" from the floor and 6" from any wall. Locate as far as possible from the bathing seating area or location of the users and not below any fixtures.
Digital Shower Package 2 Tools and Materials Back of Control Power/Data M8 connection Controller Item STCX-XXX Silicone Mud Ring Item 04-8566 Installation instructions, warranty, static cling warning label Materials needed: o SignaTouch control o M8 cable o Silicone o Mud Ring o Other materials as required 3 Mud Ring Application Top Horizontal Installation Top Vertical Installation Shower wall Mud Ring goes inside wall opening Shower wall 5.7" W by 3.
Digital Shower Package 4 Control Installation and Data Cable Connection Installation with generator only Route the M8 cable through the finished wall to the back side of the control. (The other end of the cable runs to the steam generator location.) NOTE: It is recommended to run the cable through electrical conduit. DO NOT STAPLE the cable! Shower wall M8 Cable Installation with one of or all, SLSR, Digital shower valve, and steam generator.
Digital Shower Package 5 Sealing Control THESE STEPS MUST BE TAKEN FOR CORRECT INSTALLATION OF THE CONTROL. REMOVE MUD RING FROM WALL CUTOUT BEFORE MAKING FINAL CABLE CONNECTIONS TO THE THERMATOUCH CONTROL. TEST THAT ALL CONNECTIONS ARE WORKING BEFORE SEALING THE CONTROL TO THE WALL. (Power on the control and see that it lights up). A Coat the entire edge of the control with supplied waterproof silicone to fully seal the control to the wall.
Digital Shower Package 6a Connecting SignaTouch to the Generator M8 Cable 6b Connecting SignaTouch to Serenity Light, Sound, Rainhead (if applicable) M12 Cable 110v M8 Cable THERMASOL.COM I 800.776.
Digital Shower Package 6c Connecting SignaTouch to Digital Shower 110v M12 Cable M8 Cable 6d Connecting Total Wellness Package 110v M12 Cable M8 Cable M8 Cable 8 THERMASOL.COM I 800.776.
Digital Shower Valve Installation Manual TDS-3000 OVER 60 YEARS OF STEAM SHOWER INNOVATION 9
Digital Shower Package 1 Important Information Before You Install Make sure the walls, ceiling and floor materials are suitable for use with this product. Ensure electrical power is turned off for the duration of the installation. PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER BEFORE USING THE SHOWER, TEST THE WATER TEMPERATURE WITH YOUR HAND BEFORE FULLY ENTERING THE SHOWER.
Digital Shower Package 3 System Layout Serenity Light and Sound ThermaTouch Control (Inside Shower) TT C AU D IO OU T 110V Power TT C SL SI 24 VD C IN PU T NP UT CO IN To LAN/ROUTER PDM NT PU T CO NT Steam Generator RO L2 IN RO L1 IN PU T PU T Digital Interface 110V Power UT M EA ST NIT INP U TDS-3000 Digital Shower Valve 208/240VAC Easy Start Control (Outside Shower) Water Inlets (Hot/Cold) THERMASOL.COM I 800.776.
Digital Shower Package 4 Scope of Application PDM Digital Interface TDS-3000 Digital Shower Valve IMPORTANT: The Digital Shower Valve must be accessible and should not be sealed in the wall 12 THERMASOL.COM I 800.776.
Digital Shower Package 5 Remove Cover V 15 C AC U T EX -2 RS 32 R TO MO TL I X AU 6 Inside Valve System Controller Battery Compartment Fixing Holes 15V ACCU Power Supply TLI Hot Cold Connector Block Outlets Inlets THERMASOL.COM I 800.776.
Digital Shower Package 7 Mark and Drill Holes 235mm / 9.25" 235mm / 9.25" 14 8mm / 0.31" THERMASOL.COM I 800.776.
Digital Shower Package 8 Install Valve System Controller 15 V CU AC T EX -2 RS 32 R TO MO I TL X AU 9 Remove Inlet Retaining Bolt V 15 C AC U T EX 32 -2 RS R TO MO I TL X AU THERMASOL.COM I 800.776.
Digital Shower Package 10 Connect Hot and Cold Water Supply V 15 U C AC T EX 32 -2 RS R TO MO I TL X AU 2. Insert inlet connectors 1. Connect hot and cold water supply V 15 3. re-insert retaining bolt U C AC T EX 32 -2 RS R TO MO I TL X AU IMPORTANT: Flush the pipework before connection 11 Remove Outlet Retaining Bolt V 15 CU AC T EX -2 RS 32 R TO MO I TL X AU 16 THERMASOL.COM I 800.776.
Digital Shower Package 12 Connect Outlet Pipeworks 15 V CU AC EX T -2 RS 32 R TO MO I TL X AU 3. re-insert retaining bolt V 15 2. Insert outlet connectors CU AC T EX 32 -2 RS R TO MO I TL X AU 1. Connect outlet pipeworks 1 V 15 2 CU AC T EX 2 23 RS R TO MO I TL X AU 3 2 3 1 IMPORTANT: Flush the waterlines prior to connecting to clear any debris. THERMASOL.COM I 800.776.
Digital Shower Package 13 Connect Back Up Battery V 15 CU AC T EX 32 -2 RS V R TO MO 15 CU AC I TL T EX 2 3 -2 RS X AU R TO MO TL I X AU 14 Connect The Digital Interface V 15 CU AC T EX Connect the digital interface to the RS232 port 32 -2 RS R TO MO U C AC EX T 32 -2 RS R TO MO I TL X AU THERMASOL.COM I 800.776.
Digital Shower Package 15 Connect The PDM V 15 C AC U EX T 32 -2 RS R TO MO I TL X AU V 15 U C AC T EX 32 -2 RS R TO MO I TL X AU THERMASOL.COM I 800.776.
Digital Shower Package 16 Re-fit Cover and Connect V 15 CU AC T EX 32 -2 RS R TO MO I TL X AU IMPORTANT: Electrical connection must be installed by a qualified electrician. 20 THERMASOL.COM I 800.776.
Digital Shower Package ThermaSol Product Registration Dear ThermaSol End User: Please register your product at www.thermasol.com/warranty so we can assist you much quicker if you ever need to contact our Technical Support Department. In addition we’ll keep you informed about your product and time to time we’ll update you about new products and other company announcements. Thank you from all of us at ThermaSol and we wish you many relaxing and steamy days ahead.
1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.