STEAM SELECT 1 STEAM SELECT 2 1 SELECT 2 1 STEAM 2 Installation Manual For Tutorials and Troubleshooting visit www.thermasol.
Signature Series Control Installation Instructions 1 Important Information before You Install The Signature Series Control must be installed inside the shower. The Signature Series control will only function on the current TFX, SSA and PRO Series generators. The control should be installed 60" from the floor of the shower and away from the steamhead.
Signature Series Control Installation Instructions 2 Tools and Materials Controller (Contemporary style shown here) Silicone Materials needed: o Signature Series control o CAN-Bus Cable (included with generator) o Silicone o Other materials as required Parts enclosed Mud Ring 04-8509-1 Installation instructions, warranty, static cling warning label Tools needed: o 1/2” drill for surface mount o Follow pre-installation instruction on page 5 for recessed mount controls o Drill motor o Other tools
Signature Series Control Installation Instructions 4 Control Installation and Data Cable Connection Back of Control Route the data cable (included with generator) through the finished wall to the back side of the control. The other end of the cable runs to the steam generator location or if present to PDM. NOTE: It is recommended to run the cable through electrical conduit. Connector Detail DO NOT pinch, nail, staple, wedge, or bind the data cable.
Signature Series Control Installation Instructions 5 Mud Ring Installation + Sealing Control For Recessed Controls Only (SEMR-XX) Silicone (included) Recessed Control (shown) Data Cable Step 1: BEFORE TILE - Use the supplied mud ring by attaching to wall face using a few standard screws. Then tile to the edge of the mud ring. Step 2: Once finished tile is completed remove mud ring from wall. Ensure that the total minimum depth is 5/8” so control face sits flush to wall.
Signature Series Control Installation Instructions 6 Steam Line and Steamhead Now you will need to decide on the steamhead placement in the shower so you can run the steam line from the generator to the steamhead. There are a couple of things you need to know about the placement of the steamhead and steam line itself. DO NOT install any valve in the steam line. Flow of steam must be unobstructed. The steam line can run up and then down, once; or horizontal; but never run down and then up.
Signature Series Control Installation Instructions Steamhead Location DO NOT install the steamhead near the seating area or the user. DO NOT forget to install the steamhead rough-in fitting! C I nstall the steamhead 24" from the floor or bathtub rim and 6" from any corner. Steamhead is to be mounted as far as possible from typical bathing position (seated or standing) and installed as far from the in-shower controller as possible.
Signature Series Control Installation Instructions D Once the shower wall is complete and the housing is sealed to the wall, remove the protective cap and insert the steamhead into housing. Use the supplied silicone to adherethe steamhead to the wall sealing out any water from getting behind the head. Use supplied o-ring lubricant to assist in steam head installation. A very small amount is all that is need directly on the o-rings.
Signature Series Control Installation Instructions 8 Operation For More Operating Interactive Instructions please visit: www.thermasol.com/solutions A Taking a Steam Bath On your ThermaSol Signature Series Control, touch and release the power icon to power on. To turn off the steam unit touch and release the power icon once. B Setting or Changing the Temperature Set Point Press the or button until you reach the temperature menu. Press button.
Signature Series Control Installation Instructions 9 Trouble Shooting and Error Codes Visit www.thermasol.com/solutions. Click on Troubleshoot then click on Signature Series Control Error Codes Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. 10 THERMASOL.COM I 800.776.
Signature Series Control Installation Instructions Notes: Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.
1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | SUPPORT@THERMASOL .COM | WWW.THERMASOL .COM WWW.THERMASOL .