SteamVection Steamhead Installation Manual SVRD-XX , SVSQ-XX OVER 60 YEARS OF STEAM SHOWER INNOVATION
SteamVection Steamhead Installation Instructions 1 Important Information Before You Install Make sure the walls, ceiling and floor materials are suitable for use with steam. If using acrylic walls, they must be steam rated from their manufacturer. ThermaSol only recommends specific generators for acrylic modules. Ensure electrical power is turned off for the duration of the installation.
SteamVection Steamhead Installation Instructions 2 Steam Line and Steamhead Now you will need to decide on the steamhead placement in the shower so you can run the steam line from the generator to the steamhead. There are a couple of things you need to know about the placement of the steamhead and steam line itself. DO NOT install any valve in the steam line. Flow of steam must be unobstructed. A The steam outlet on the generator requires a 1/2" brass union for easy installation (not included).
SteamVection Steamhead Installation Instructions Steamhead Location DO NOT install the steamhead near the seating area or the user. DO NOT forget to install the steamhead rough-in fitting! C I nstall the steamhead 24" from the floor or bathtub rim and 6" from any corner. Steamhead is to be mounted as far as possible from typical bathing position (seated or standing) and installed as far from the in-shower controller as possible.
SteamVection Steamhead Installation Instructions D Once the shower wall is complete and the housing is sealed to the wall, remove the protective cap and insert the steamhead into housing. Use the supplied silicone to adherethe steamhead to the wall sealing out any water from getting behind the head. Use supplied o-ring lubricant to assist in steam head installation. A very small amount is all that is need directly on the o-rings.
1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.