Installation Sheet

92026-390_A 7/17
TFXA-390
FX SERIES Auto Flush Steam Generator
Rough-In Guide
Shipping Information:
Weight……………28 lbs.
Length………………..…21 in.
Width……………....….10.5 in.
Height…………...…..14 in.
FX Series Auto Flush Steam Generator
SPECIFICATIONS
Input Voltage………….......208-240VAC Single Phase
Kilowatt Rating……………………………………………..11.0
Maximum Amperage……………………………..….55 AMPS
Breaker Size………………………………………..….60AMPS
Water Inlet………………………….…...3/8” Compression
Steam Outlet…………………………………….…….1/2” NPT
Drain Pan………………………………….…...………3/4” NPT
Safety Valve………………………………………..….3/4” NPT
Electrical Connection…………………..............Hardwired
Maximum Room Size (Cubic Feet)………..………..…...395
For any further assistance please contact ThermaSol at
800.776.0711 or sales@thermasol.com
Installation Notes:
Generator must be installed by a licensed electrician.
Install this generator according to the installation guide supplied. Follow all local plumbing and electrical codes. Unit must be accessible for
service and maintenance. Generator is factory sized: L x W x H = Steam Room Cubic Feet = 395 Cu. Ft. max. Choose the appropriate generator.
For every additional foot of ceiling height over 8 ft, use the next larger generator. Always round up when calculating the total cubic feet.
Product Specification Basics:
The steam generator unit dimensions are approximately 18-3/4”L x
18-1/8”W x 12-3/4”H in dimension. The generator shall be made
from stainless steel.
FX Series Auto Flush Series Standard Equipment:
Auto PowerFlush Pressurized inner tank cleaning system
Includes Fast Start Steam in seconds… not minutes
Constant Steam at a constant rate
Unit has 208-240 volt power connections to be installed by your
licensed electrician
Superior heating element low watt density
Includes Stainless Steel drain pan