Installation Sheet

92027-390_A 7/17
TFXM-390
FX SERIES Manual Flush Steam Generator
Rough-In Guide
Shipping Information:
Weight……………25 lbs.
Length……………..…21 in.
Width……………....….10.5 in.
Height………….....14 in.
FX Series Manual Flush Steam Generator
SPECIFICATIONS
Input Voltage………….……......208-240VAC Single Phase
Kilowatt Rating………………………………………..…..11.0
Maximum Amperage…………………………......55 AMPS
Breaker Size……………………………………....….60 AMPS
Water Inlet………………………….…...3/8” Compression
Steam Outlet…………………………………….…….1/2 NPT
Safety Valve………………………………………..….3/4” NPT
Electrical Connection………………………….....Hardwired
Maximum Room Size (Cubic Feet)………..……….....395
For any further assistance please contact ThermaSol at
800.776.0711 or sales@thermasol.com
Installation Notes:
Generator must be installed by a licensed electrician.
Install this generator according to the installation guide supplied. Follow all local plumbing and electrical codes. Unit must be accessible for
service and maintenance. Generator is factory sized: L x W x H = Steam Room Cubic Feet = 395 Cu. Ft. max. Choose the appropriate generator.
For every additional foot of ceiling height over 8 ft, use the next larger generator. Always round up when calculating the total cubic feet.
Product Specification Basics:
The steam generator unit dimensions are approximately 17-3/4”L x
6-1/8”W x 12-3/4H in dimension. The generator shall be made from
stainless steel.
FX Series Manual Flush Series Standard Equipment:
Manually Operated PowerFlush Pressurized inner tank cleaning system
Includes Fast Start Steam in seconds… not minutes
Constant Steam at a constant rate
Unit has 208-240 volt power connections to be installed by your licensed
electrician
Superior heating element low watt density

Summary of content (1 pages)