ThermaTouch Control Installation Manual For Tutorials and Troubleshooting visit www.thermasol.
ThermaTouch Control Installation Instructions 1 Important Information before You Install The ThermaTouch Control must be installed inside the shower. The ThermaTouch control will only function on the current TFX, SSA and PRO Series generators. The control should be installed 60" from the floor of the shower and away from the steamhead. The steamhead should be installed 24" from the floor and 6" from any wall.
ThermaTouch Control Installation Instructions 2 Tools and Materials Controller Item TT7X-XX Silicone 25-foot Yellow M12 Cable Item 03-7149-25 Power Supply Brick Item 03-7142 PDM Item 10-8147 Materials needed: Mud Ring Item 04-8544 Installation instructions, warranty, static cling warning label Back of Control o ThermaTouch control o M12 cable Power/Data M12 connection o Silicone o Power Distribution Module (PDM) Plug in network cable RJ-45 for updates over the internet o Mud Ring o Ethernet Ca
ThermaTouch Control Installation Instructions 4 Control Installation and Data Cable Connection Shower wall Route the M12 cable through the finished wall to the back side of the control. (The other end of the cable runs to the PDM location.) NOTE: It is recommended to run the cable through electrical conduit. DO NOT STAPLE the cable! 3.
ThermaTouch Control Installation Instructions 5 Sealing Control THESE STEPS MUST BE TAKEN FOR CORRECT INSTALLATION OF THE CONTROL. REMOVE MUD RING FROM WALL CUTOUT BEFORE MAKING FINAL CABLE CONNECTIONS TO THE THERMATOUCH CONTROL. TEST THAT ALL CONNECTIONS ARE WORKING BEFORE SEALING THE CONTROL TO THE WALL. (Power on the control and see that it lights up). A Coat the entire groove on the control back with supplied waterproof silicone to fully seal the control to the wall.
ThermaTouch Control Installation Instructions 6a Connecting ThermaTouch to Generator 110v TTC SLS M8 Cable M12 Cable 6b Connecting ThermaTouch to Serenity Light, Sound, Rainhead 110v M12 Cable Audio Cable TTC SLS M12 Cable Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. 6 THERMASOL.COM I 800.776.
ThermaTouch Control Installation Instructions 6c Connecting ThermaTouch to Digital Shower 110v M12 Cable Audio Cable TTC SLS M12 Cable 6b Connecting Total Wellness Package 110v M12 Cable Audio Cable M8 Cable TTC SLS M12 Cable Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.
ThermaTouch Control Installation Instructions 7 Steam Line and Steamhead Now you will need to decide on the steamhead placement in the shower so you can run the steam line from the generator to the steamhead. There are a couple of things you need to know about the placement of the steamhead and steam line itself. DO NOT install any valve in the steam line. Flow of steam must be unobstructed. The steam line can run up and then down, once; or horizontal; but never run down and then up.
ThermaTouch Control Installation Instructions Steamhead Location DO NOT install the steamhead near the seating area or the user. DO NOT forget to install the steamhead rough-in fitting! C I nstall the steamhead 24" from the floor or bathtub rim and 6" from any corner. Steamhead is to be mounted as far as possible from typical bathing position (seated or standing) and installed as far from the in-shower controller as possible.
ThermaTouch Control Installation Instructions D Once the shower wall is complete and the housing is sealed to the wall, remove the protective cap and insert the steamhead into housing. Use the supplied silicone to adherethe steamhead to the wall sealing out any water from getting behind the head. Use supplied o-ring lubricant to assist in steam head installation. A very small amount is all that is need directly on the o-rings.
ThermaTouch Control Installation Instructions 9 Trouble Shooting, Tutorials and Error Codes Visit www.thermasol.com/solutions. Click on Troubleshoot then click on ThermaTouch Control Error Codes. Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. THERMASOL.COM I 800.776.
1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.