Total Wellness Package Installation Manual For Tutorials and Troubleshooting visit www.thermasol.
ThermaTouch Control 10 Inch Screen Installation Manual For Tutorials and Troubleshooting visit www.thermasol.
Total Wellness Package 1 Important Information before You Install The ThermaTouch Control must be installed inside the shower. The ThermaTouch control will only function on the current TFX, SSA and PRO Series generators. The control should be installed 60" from the floor of the shower and away from the steamhead. The steamhead should be installed 24" from the floor and 6" from any wall. Locate as far as possible from the bathing seating area or location of the users and not below any fixtures.
Total Wellness Package 2 Tools and Materials Controller Item TT7X-XX Silicone 25-foot Yellow M12 Cable Item 03-7149-25 Power Supply Brick Item 03-7142 PDM Item 10-8147 Materials needed: Mud Ring Item 04-8544 Installation instructions, warranty, static cling warning label Back of Control o ThermaTouch control o M12 cable Power/Data M12 connection o Silicone o Power Distribution Module (PDM) Plug in network cable RJ-45 for updates over the internet o Mud Ring o Ethernet Cable with RJ-45 Connecto
Total Wellness Package 4 Control Installation and Data Cable Connection Shower wall Route the M12 cable through the finished wall to the back side of the control. (The other end of the cable runs to the PDM location.) NOTE: It is recommended to run the cable through electrical conduit. DO NOT STAPLE the cable! 3.5mm male audio cable (not included unless Serenitiy Light, Sound, Rain Head was purchased) Run the M12 cable so the 90-degree end connection will connect to the ThermaTouch control.
Total Wellness Package 5 Sealing Control THESE STEPS MUST BE TAKEN FOR CORRECT INSTALLATION OF THE CONTROL. REMOVE MUD RING FROM WALL CUTOUT BEFORE MAKING FINAL CABLE CONNECTIONS TO THE THERMATOUCH CONTROL. TEST THAT ALL CONNECTIONS ARE WORKING BEFORE SEALING THE CONTROL TO THE WALL. (Power on the control and see that it lights up). A Coat the entire groove on the control back with supplied waterproof silicone to fully seal the control to the wall.
Total Wellness Package 6a Connecting ThermaTouch to Generator 110v TTC SLS M8 Cable M12 Cable 6b Connecting ThermaTouch to Serenity Light, Sound, Rainhead 110v M12 Cable Audio Cable TTC SLS M12 Cable THERMASOL.COM I 800.776.
Total Wellness Package 6c Connecting ThermaTouch to Digital Shower 110v M12 Cable Audio Cable TTC SLS M12 Cable 6b Connecting Total Wellness Package 110v M12 Cable Audio Cable M8 Cable TTC SLS M12 Cable 8 THERMASOL.COM I 800.776.
Total Wellness Package 7 Steam Line and Steamhead Now you will need to decide on the steamhead placement in the shower so you can run the steam line from the generator to the steamhead. There are a couple of things you need to know about the placement of the steamhead and steam line itself. DO NOT install any valve in the steam line. Flow of steam must be unobstructed. The steam line can run up and then down, once; or horizontal; but never run down and then up.
Total Wellness Package Steamhead Location DO NOT install the steamhead near the seating area or the user. DO NOT forget to install the steamhead rough-in fitting! C I nstall the steamhead 24" from the floor or bathtub rim and 6" from any corner. Steamhead is to be mounted as far as possible from typical bathing position (seated or standing) and installed as far from the in-shower controller as possible.
Total Wellness Package D Once the shower wall is complete and the housing is sealed to the wall, remove the protective cap and insert the steamhead into housing. Use the supplied silicone to adherethe steamhead to the wall sealing out any water from getting behind the head. Use supplied o-ring lubricant to assist in steam head installation. A very small amount is all that is need directly on the o-rings.
HydroVive Installation Manual For Tutorials and Troubleshooting visit www.thermasol.
Total Wellness Package 1 Important Information Before You Install PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH. PLEASE CONSULT YOUR PHYSICIAN BEFORE USING. IF YOU ARE PREGNANT, ELDERLY, HAVE HIGH BLOOD PRESSURE, DIABETES, SUFFERING FROM HEART DISEASE, ARE INTOXICATED, OR NOT IN GOOD HEALTH, DO NOT USE THIS STEAM BATH.
Total Wellness Package 2 Tools and Materials Parts Enclosed: HydroVive Light, Sound, Rain Head fixture and hardware Item HVLSRSQ-XX Wood Screw Silicone #10 x 3.
Total Wellness Package 3 Placement and Cutout Cut a 16.7" square out of your ceiling and frame it in. Cutout Sizing Once framed in, you’ll want a minimum clearance of 14.45" x 14.25" for comfortable installation. Framing studs should be on 16" Centers. Put all your connections through the hole as the rest of the installation will be completed from inside the shower. 14.25" 16.7" NOTE: HydroVive weighs 37 lbs. It must be mounted to a framed structure that can support its weight. 14.25" 14.5" 16.
Total Wellness Package 4 Mounting Brackets Measure and locate the midpoints on each 14.25" side of the cutout. The midpoints are where you’ll install the mounting brackets, each mounting bracket will require 4–3/4" (included) wood screws. WARNING: READ BEFORE PROCEEDING: The HydroVive weighs 37 lbs. and overhead lifting is required to continue installation. Please be cautious and practice ladder safety.
Total Wellness Package 7 Sealing HydroVive Apply silicone along the groove on the back of HydroVive. 8 Move Into Place Guide the HydroVive into the ceiling and rest it on the highest hook you can reach. Use the 3.5" included mounting screws, and gradually insert them a little at a time to evenly lift the HydroVive into position to create a seal with the previously applied silicone.
Digital Shower Valve Installation Manual TDS-3000 OVER 60 YEARS OF STEAM SHOWER INNOVATION 18
Total Wellness Package 1 Important Information Before You Install Make sure the walls, ceiling and floor materials are suitable for use with this product. Ensure electrical power is turned off for the duration of the installation. PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER BEFORE USING THE SHOWER, TEST THE WATER TEMPERATURE WITH YOUR HAND BEFORE FULLY ENTERING THE SHOWER.
Total Wellness Package 3 System Layout Serenity Light and Sound ThermaTouch Control (Inside Shower) TT C AU D IO OU T 110V Power TT C SL SI 24 VD C IN PU T NP UT CO IN To LAN/ROUTER PDM NT PU T CO NT Steam Generator RO L2 IN RO L1 IN PU T PU T Digital Interface 110V Power UT M EA ST NIT INP U TDS-3000 Digital Shower Valve 208/240VAC Easy Start Control (Outside Shower) 20 Water Inlets (Hot/Cold) THERMASOL.COM I 800.776.
Total Wellness Package 4 Scope of Application PDM Digital Interface TDS-3000 Digital Shower Valve IMPORTANT: The Digital Shower Valve must be accessible and should not be sealed in the wall THERMASOL.COM I 800.776.
Total Wellness Package 5 Remove Cover V 15 C AC U T EX -2 RS 32 R TO MO TL I X AU 6 Inside Valve System Controller Battery Compartment Fixing Holes 15V ACCU Power Supply TLI Hot Cold Outlets Inlets 22 THERMASOL.COM I 800.776.
Total Wellness Package 7 Mark and Drill Holes 235mm / 9.25" 235mm / 9.25" 8mm / 0.31" THERMASOL.COM I 800.776.
Total Wellness Package 8 Install Valve System Controller 15 V CU AC T EX -2 RS 32 R TO MO I TL X AU 9 Remove Inlet Retaining Bolt V 15 C AC U T EX 32 -2 RS R TO MO I TL X AU 24 THERMASOL.COM I 800.776.
Total Wellness Package 10 Connect Hot and Cold Water Supply V 15 U C AC T EX 32 -2 RS R TO MO I TL X AU 2. Insert inlet connectors 1. Connect hot and cold water supply V 15 3. re-insert retaining bolt U C AC T EX 32 -2 RS R TO MO I TL X AU IMPORTANT: Flush the pipework before connection 11 Remove Outlet Retaining Bolt V 15 CU AC T EX -2 RS 32 R TO MO I TL X AU THERMASOL.COM I 800.776.
Total Wellness Package 12 Connect Outlet Pipeworks 15 V CU AC EX T -2 RS 32 R TO MO I TL X AU 3. re-insert retaining bolt V 15 2. Insert outlet connectors CU AC T EX 32 -2 RS R TO MO I TL X AU 1. Connect outlet pipeworks 1 V 15 2 CU AC T EX 2 23 RS R TO MO I TL X AU 3 2 3 26 1 IMPORTANT: Flush the waterlines prior to connecting to clear any debris. THERMASOL.COM I 800.776.
Total Wellness Package 13 Connect Back Up Battery V 15 CU AC T EX 32 -2 RS V R TO MO 15 CU AC I TL T EX 2 3 -2 RS X AU R TO MO TL I X AU 14 Connect The Digital Interface V 15 CU AC T EX Connect the digital interface to the RS232 port 32 -2 RS R TO MO I TL X AU RS232 Port V 15 U C AC EX T 32 -2 RS R TO MO I TL X AU THERMASOL.COM I 800.776.
Total Wellness Package 15 Connect The PDM V 15 C AC U EX T 32 -2 RS R TO MO I TL X AU V 15 U C AC T EX 32 -2 RS R TO MO I TL X AU 28 THERMASOL.COM I 800.776.
Total Wellness Package 16 Re-fit Cover and Connect V 15 CU AC T EX 32 -2 RS R TO MO I TL X AU IMPORTANT: Electrical connection must be installed by a qualified electrician. THERMASOL.COM I 800.776.
Total Wellness Package ThermaSol Product Registration Dear ThermaSol End User: Please register your product at www.thermasol.com/warranty so we can assist you much quicker if you ever need to contact our Technical Support Department. In addition we’ll keep you informed about your product and time to time we’ll update you about new products and other company announcements. Thank you from all of us at ThermaSol and we wish you many relaxing and steamy days ahead.
THERMASOL.COM I 800.776.
1958 STEAM WAY ROUND ROCK, TX 78665 PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.