Installation Sheet
Shower 
wall
Route the M8 cable through the nished wall to the back side 
of the control. (The other end of the cable runs to the steam 
generator location.) NOTE: It is recommended to run the 
cable through electrical conduit. DO NOT STAPLE the cable!
Connect the data cable to Power Distribution Module 
(PDM). (The other end of the cable runs to the back of the 
control in the shower location.)
THERMASOL.COM 
I
 800.776.0711
DO NOT pinch, nail, staple, wedge, or 
bind the data cable. 
DO NOT wrap the data cable around 
steam line or route it in a manner so 
that the hot steam line could melt 
the cable.
Any damage to the control cable 
will result in the control not working 
properly.
Carefully connect the data cable to 
the PDM and control BEFORE turning 
power on to the generator or PDM.
"ON" 
Turn Clockwise
"OFF" Turn 
Counter Clockwise
• Do not staple, strain or damage data cable
• Align pins to receptacle visually before tightening
• Do not force plug
• Hand tighten only
Connector 
Detail
Connect to PDM
PDM requires 110V power
Contact pins
4 Control Installation and Data Cable Connection
Contact pins Cable ends
M8 Cable
Installation with  
generator only
Installation with one of or all, SLSR, Digital 
shower valve, and steam generator. 
Total Wellness Package
5