Now you will need to decide on the steamhead placement in the shower so you can run the steam line from the generator to the 
steamhead. There are a couple of things you need to know about the placement of the steamhead and steam line itself.
24"
6"
B
7 Steam Line and Steamhead
A
C
Steam Line
Shown installed 
in attic 
DO NOT install any valve in the steam line. Flow of steam must 
be unobstructed.
DO NOT plumb any traps in the steam line.
The steam outlet on the generator requires a 1/2" brass 
union for easy installation (not included).
Use 1/2” brass pipe or copper tubing from unit to 
steamhead rough-in tting as permitted by code.
A
B
The steam line can run up and then down, once; or horizontal; 
but never run down and then up. If it does, a steam trap will 
be produced at the low point blocking the ow of steam.
 Insulate the steam outlet piping if the piping run exceeds 10 feet or 
is exposed to cold areas. Use steam rated insulation.
 Pitch/angle steam lines back towards generator before any up or 
down turns; pitch/angle towards steam room after any up or down 
and avoid perfectly level plumbed lines.