Operating Manual
Chapter 8 Serial Ports, Contact Inputs & Special Fcts Accu-Wave 
8-12 TN Technologies 
Set Up Data Format (Non-Packet Text Data) Menu 
The “Set Up Data Format” menu items for non-packet data are displayed if “Do not 
transmit data in packet format” is selected in the “Set up port … transmission data” menu. 
These menu items establish the formatting used for non-packet text transmission (for 
example, labeling, tabulation, and pagination) for measurements sent to a terminal or 
printer. 
In the following menu items, a reading refers to a particular measurement such as level or 
volume. A data set refers to all the readings being transmitted by a particular unit (gauge). 
By default, a NEWLINE is sent after each reading. A HOME and a CLEAR are sent after 
each data set. This causes the data to update at the same place on the screen. 
The “Set up data format” menus for non-packet data are identical for the RS-232 and the 
RS-485 ports except for the references to the port number. The table below shows the 
menu items as they appear for the RS-232 port. 
“Set Up Data Format (Non-Packet Data)” Menu 
Display  Comments 
Set up data format.→→ 
 NEXT↓↓ 
The following non-packet format menu items are 
displayed if “Do not transmit … packet format” was 
selected in the “Set up port … data transmission” 
menus. The menu items are identical for the RS-232 
and RS-485 ports. 
Do not put meas num 
before each reading. 
Change to “Do”→→ 
Continue as is.↓↓ 
Select “Do” to put the measurement number (1 to 8) 
before each reading. 
Do send NEWLINE 
after each reading. 
Change to “Do not”→→ 
Continue as is.↓↓ 
“Do” sends a logical NEWLINE after each reading. 
“Do not” suppresses the NEWLINE. 
Do send units 
 with each reading. 
Change to “Do not”→→ 
Continue as is.↓↓ 
“Do” sends the measurements unit string (ft level, sig 
str, cu M, etc). “Do not” suppresses the units string. 
Do not put unit num 
before each reading. 
Change to “Do”→→ 
Continue as is.↓↓ 
Applies to RS-485 party line communications only. 
Sends the gauge unit number with each reading. 
Do not put TAB 
after each reading. 
Change to “Do”→→ 
Continue as is.↓↓ 
Change to “Do” to append a TAB (ASCII char 9) 
after each reading. Useful for sending columnar data 
to a printer. 