Operating Manual
Accu-Wave Chapter 3 Set up Level, Level Alarms, and Volume 
TN Technologies 3-3 
“Set up Level” menu. The “Comments” column of the table describes the purpose of each 
menu item. An example showing the specific entries required to set up level as the primary 
measurement is provided immediately following this table. 
 “Set up Level” Menu 
Display  Comments 
Set up level, level 
alarms & volume 
←←Exit Setup. 
 Other functions→→ 
From the measurement display, press → to move to 
the “Set up level,...” menu shown at the left. Press ↓ 
to access the “Set up level,…” menu items. 
Note: The software detects whether output relays 
are installed. If no relays are present, the 
menu will display “Set up level & volume.”  
General HELP text.→→ 
Information on how 
to set up this gauge 
 NEXT↓↓ 
We strongly suggest you read the HELP screens, 
especially when you are first learning to set up the 
gauge. Press ↓ to proceed to the next menu item. 
primary measurement: 
Distance 
Change to Level→→ 
 NEXT↓↓ 
The primary measurement can be either distance or 
level. Distance is the default. 
Allow display of ALL 
units. Change to 
 Metric or English→→ 
 NEXT↓↓ 
Select the desired set of units for the primary 
measurement using the → key. The default is ALL 
which includes both English and Metric units. 
English units are - in, ft, and yd. Metric units are - 
mm, cm, and M. 
Distance units = ft 
To change to yd, M, 
cm, mm, or in press→→ 
 NEXT↓↓ 
Scroll through and select desired measurement units 
using the → key. The available units depend on 
previous menu item selection of ALL, English, or 
Metric units. 
Note: The next two menu items define the Range of Interest, the range over which 
the gauge looks for the echo from the process material surface. The values 
to be entered depend on whether distance or level is selected as the primary 
measurement. 










