Operating Manual
Accu-Wave Chapter 4 Set up Additional Measurements 
TN Technologies 4-1 
Chapter 4 Set up Additional Measurements 
As described in Chapter 3, the primary measurement (measurement #1) is set up as either 
level or distance using the “Set up level,...” menu. Up to seven additional measurements 
can be set up using the “Set up additional measurements” menu. You can use these 
measurements to drive a variety of alarms and current outputs to meet the needs of your 
processing procedures. 
To reach the “Set up additional measurements” menu from the measurement display, press 
→ twice. Then press ↓ to enter the menu.  
The first time you access the “Set up Additional Measurements” menu, the “Assign & set 
up measurement 2” menu will appear. Measurement 1 is assigned to the primary 
measurement (distance or level) by default. After measurement 2 is set up, the next time 
you scroll through this menu item, it will read “Modify setup of measurement 2.” You will 
then be able to “Assign & setup measurement 3,” and so on, up to a maximum of eight 
measurements. 
The following sections describe the “Set up additional measurements” menu items. The 
tables at the end of this Chapter show the individual menu items and the sequence in which 
they are displayed. 
Selecting Measurement Type 
The “Reading presented by measurement # is” menu item allows you to specify the desired 
measurement type. Available measurements include: 
• distance (outage) 
• level 
• volume 
• ullage (empty volume) 
• percent full 
• percent empty 
• percent distance 
• per cent level 
• signal strength (sig str) 
• mass 
• rate 
• special measurements, for service diagnostics  
Note: Volume related measurements (volume, ullage, % full, % empty, and mass) 
are not available for selection until “Tank volume setup” has been 
completed under the “Set up Level, Level Alarms, and Volume” menus. 
Special measurements are only available when “Service only items” are 
enabled (see “Special Functions” on page 8-19).  