TABULAR DATA SHEET
Outdoor Split System Heat Pump 1.5 Thru 5 Tons
MODELS: THJD18* THRU 60
13 SEER – R-410A, 1 PHASE
All dimensions are in inches. They are subject to change without notice.
Certified dimensions will be provided upon request.
Physical and Electrical Data
MODEL
THJD18
S41S3
THJD24
S41S4
THJD30
S41S4
THJD36
S41S4
THJD42
S41S4
THJD48
S41S4
THJD60
S41S4
Unit Supply Voltage 208-230V, 1 60Hz
Normal Voltage Range
1
187 to 252
Minimum Circuit Ampacity 11.9 11.2 14.1 19.7 20.9 25.6 34.9
Max. Overcurrent Device Amps
2
20 15 20 30 35 45 60
Min. Overcurrent Device Amps
3
15 15 15 20 25 30 35
Compressor Type Scroll Recip Recip Recip Recip Recip Scroll
Compressor
Amps
Rated Load 9.0 8.3 10.6 14.7 15.7 19.4 26.9
Locked Rotor 48.0 43.0 54.0 74.0 88.0 88.0 135.0
Crankcase Heater No Yes Yes Yes Yes Yes No
Factory External Discharge Muffler Yes No No No No No Yes
Factory External Check Valve NoNoNoNoNoNoNo
HS Kit Required with TXV
4
No Yes Yes Yes Yes Yes* No
Fan Motor Amps Rated Load 0.70 0.80 0.80 1.3 1.3 1.3 1.3
Fan Diameter Inches 24 24 24 24 24 24 24
Fan Motor
Rated HP 1/10 1/8 1/8 1/4 1/4 1/4 1/4
Nominal RPM 825 1075 1075 850 850 850 850
Nominal CFM 2000 2900 3000 3800 3800 3600 3600
Coil
Face Area Sq. Ft. 15.7 18.3 21.0 23.6 23.6 23.6 23.6
Rows Deep 1 1 1 1 1 2 2
Fin / Inches 22 22 22 22 22 18 18
Liquid Line Set OD (Field Installed) 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Vapor Line Set OD (Field Installed) 3/4 3/4 3/4 3/4 7/8 7/8 7/8
Unit Charge (Lbs. - Oz.)
5
6 - 6 9 - 6 9 - 0 10 - 0 9 - 10 14 - 12 13 - 13
Charge Per Foot, Oz. 0.62 0.62 0.62 0.62 0.67 0.67 0.67
Operating Weight Lbs. 172 194 206 218 218 285 284
* These models are shipped with a Hard Start Kit installed at the factory.
1. Rated in accordance with ANSI/AHRI Standard 110-2002, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add
or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
B
C
A
Unit
Model
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
A
1
1. Including Fan Guard.
B C Liquid Vapor
18 28
34 34
3/8”
3/4”
24 32 34 34
30 36 34 34
36 40 34 34
42 40 34 34
7/8”48 40 34 34
60 40 34 34
MAC-220
ECN 5287-MA 121005