User's Manual

System Charge for Various Matched Systems
Outdoor Unit
THJD18
S41S3
THJD24
S41S4
THJD30
S41S4
THJD36
S41S4
THJD42
S41S4
THJD48
S41S4
THJD60
S41S4
Required Orifice or
TXV
1
.051/4F1 .054/4G1 .063/4G1 .071/4H1 .075/4H1 4J1 4K1
Factory Charge,
lbs-oz
6 – 6 9 – 6 9 – 0 10 – 0 9 – 10 14 – 2 13 - 13
Indoor Unit
2,3
Additional Charge, oz
FC/MC/PC/UC18 .051/TXV+0 -- -- -- -- -- --
FC/MC/PC/UC35 -- .059/TXV+0 .063/TXV+0 -- -- -- --
FC/MC/PC/UC43 -- .059/TXV+23 .063/TXV+25 .071/TXV+6 -- -- --
FC/MC/PC/UC60 -- -- -- -- .075/TXV+0 TXV_0 --
FC/PC/62 -- -- -- -- -- TXV+25 TXV+0
Footnotes:
1. For applications requiring a TXV use S1-1TVM*** series kit.
2. Systems matched with furnaces or air handlers not equipped with blower-off delays may require blower Time Delay Kit S1-2FD06700224.
3. PC coils cannot be used in downflow or horizontal applications. FC coils cannot be sued in horizontal applications.
Procedures:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the outdoor unit, the smallest matched indoor unit, and 15 feet of
interconnecting line tubing.
2. Verify the TXV or orifice and additional charge required for specific matched indoor unit in the system using the above table.
3. Add additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data
table.
4. For indoor matches requiring additional charge, the refrigerant needs to be weighed in for specific matched indoor unit and line set lengths.
5. Permanently mark the unit nameplate with the total system charge. Total system charge = base charge as shipped plus charge adder for
matched indoor unit and charge adder for line set.