Instruction Manual
4
4
FLO-DRI lter installation instructions
4
FLO-DRI lter installation instructions / Cartridge Media
C. FLO-DRI FILTER INSTALLATION INSTRUCTIONS
1. For maximum efciency, FLO-DRI unit should be
installed as indicated in Figure 1.
2. Install in a vertical position only.
3. Tighten ttings into casting 5.5 to 6.0 turns. Do not
over-tighten threaded connections. This may lead to
thread damage or possible cracking of the casting.
4. Ensure ow direction is as indicated on the unit.
5. Installation of drain leg is highly recommended.
F
L
O
W
SHUT-OFF VALVE
OUTLET
INLET
UNION
SHUT-OFF VALVE
UNION
OVERALL DIAMETER
PORT TO PORT
2"
50.8mm
3"
76.2mm
0.375"
9.5mm
0.5"
12.7mm
4.5"
114.5mm
Figure 1 – G-10 & M-10 Assembly Diagram
Table1 – Scrubbing system
Scrubbing
System
Model No. PSIG
No. of
Cartridges
Overall
Length
Overall
Diameter
Port to
Port
Pipe
Size
NPT
Bed
Cubic
in
3
Cartridge Media
Part No.
in m in mm in mm
Natural Gas FLODRI-G10A
150 1 8.50 216 4.00 102 5.00 127 1/4 12.56
FLODRI-10AA
FLODRI-10AC
FLODRI-10MS
Compressed
Air
FLODRI-M10A FLODRI-10R
D. CARTRIDGE MEDIA
D.1 Natural Gas
AA - Moisture Removal
AC - Odor Removal
MS - H
2
S & Moisture Removal
D.2 Compresssed Air Cartridge Media
R - Moisture, Oil and Heavy Liquids Removal, Air
Purier