Application Tag Commands
Command Set 109
timeout of 1000 ms. Note the Options field, no metadata is requested unlike the previous
example.
EPC ID = 0x0123456789ABCDEF01234567.
The User Memory bank is not locked so the Access Password is zero
The response to this Read Data command example is:
Note: Try changing the value at this memory location with the Write Tag Data Examples showing
writing to the same tag.
Get Tag Data and Meta Data
In addition to getting the tag data returned you can also get Tag Read Meta Data for the
found tag. This version of Read Tag Data requires bit 4 of the Option flag to be set and
takes an additional Metadata Flags field which defines what metadata will be returned.
The following table lists the supported values for these fields.
FF 1A 28 03 E8 01 03 00 00 00 02 04 00 00 00 00
SOH Lengt
h
OpCode Time-
out (ms)
Option Read
MemBank
Read Address Word-
Count
Access Password
60 01 23 45 67 89 AB CD EF 01 23 45 67 7A C1
Select
Data
Length
Select Data CRC
FF 09 28 00 00 01 AA BB CC DD 00 00 00 00 E7 54
SOH Length OpCod
e
Status Option Data Read CRC