Owner manual

Application Tag Commands
Command Set 141
response is:
ChangeConfig embedded in a Read Tag Multiple takes the following form:
Impinj Monza 4 Silicon (Chip Type=0x08)
Tags with the Impinj Monza 4 chip support custom functionality providing protection of
data through public and private data profiles and the use of short range reading options.
These are controlled through custom commands as defined by the Impinj Monza 4
datasheet (IPJ_Monza4Datasheet_20101101.pdf (please contact Impinj for more details.
QT Read/Write
The QT command controls the switching of Monza 4QT between the Private and Public
profiles. The tag MUST be in the Secured state to succeed.
FF 09 2D 00 00 07 44 00 07 00 00 ?? ??
SOH Length OpCode Status Chip
Type
Option Sub
Cmd
New Config-
Word Value
CRC
FF 19 22 04 00 04 03 E8
11 22 33 44 00 00 00 78 08 34
SOH Length OpCode Options
(EPC Mem)
Search
Flags
Timeout Access Password Select Data Address
(bits)
Select
Data
Length
(bits)
Select
Data
01 09 2D
00 00
07 40
00 07
00
00 00 ?? ??
Embd
Cmd
Count
Embd
Cmd
Length
Embd
Cmd
OpCode
Embd Cmd
Timeout
(Not Used)
Chip
Type
Option Sub Cmd RFU Config Data CRC