Owner manual

Demo Application
204 Appendix B: Getting Started - Devkit
Set Current Tag Protocol Command
When the application FW first starts, there is no default protocol loaded. Thus, the
protocol to use must be specified.
For this example, the protocol is set to EPC0 using the Set Current Tag Protocol
command:
C:\> ArbSer –msg 02 93 00 01
< Equivalent to: FF 02 93 00 01 51 79 >
Valid message received:
Data Length = 00
OpCode = 93
Status = 00 00
CRC = 371A
Set Read TX Power Command
The default read power setting for the modules is 26.5 dBm. This should be adequate to
read the tag from 1 foot. If a different power setting is desired, it should be entered now.
The following Set Read TX Power command sets the power level to 25.0 dBm (0x09C4):
C:\> ArbSer –msg 02 92 09 C4
< Equivalent to: FF 02 92 09 C4 FC E5 >
Valid message received:
Data Length = 00
OpCode = 92
Status = 00 00
CRC = 273B
Set Antenna Port Command
The default antenna port configuration is a 2-port antenna, with TX on port 1 and RX on
port 2. If a different configuration is being used, it should be changed before attempting to