Setup Guide
Table Of Contents
- Notices
- About Thinkify, LLC
- A Quick RFID Introduction
- Thinkify Reader Protocol Overview
- Command Reference
- Summary
- "A" – RX Amplifier Control
- "BOOTLOADER" – Enter Bootloader
- "C" – Low-Level Chip Control Registers
- "F" – RX Filter Control
- "G" – GPIO Settings
- “I” – Inventory Control
- "K" – Kill, Lock, Access Descriptors
- “M" – MASK / SELECT control
- “NM" – Macro Control
- "P" – PROTOCOL control (Gen2 Air protocol)
- "R" – RF Control
- "RP" and "RM" – Multiplexing (Antenna Control)
- "T" – Initiate INVENTORY
- "X" – eXtra Data Read and Write Descriptor Control
Command Structure
Examples
1. Set the General Purpose Output (GPO) Pin 1 to a High Level:
<COMMAND=”G”><SUBCOMMAND=”1”><PARAM1=”1”><TERM=0x0D>
The Host would send the string:
G11<CR>
The Reader would respond with:
GPOUT1=1<CRLF>
READY>
2. Read Tags using the “T” command:
<COMMAND=”T”>
Host:
T<CR>
Reader:
STARTINVENTORY<CRLF>
TAG=3000100000000000000000003560<CRLF>
TAG=3000100000000000000000003568<CRLF>
TAG=300010011002100310041007BBBB<CRLF>
TAG=3000100000000000000000003583<CRLF>
TAG=3000100000000000000000003556<CRLF>
TAG=3000100000000000000000003569<CRLF>
TAG=3000100000000000000000003557<CRLF>
TAG=3000BBAA99887766554433221100<CRLF>
TAG=3000100000000000000000003582<CRLF>
STOPINVENTORY 0x00EA EPCCOUNT=9<CRLF>
<CRLF>
READY>
3. Query the Inventory Parameter Settings:
<COMMAND=”I”>
Host:
I<CR>
Reader:
SESSION=1<CRLF>
TARGET=0<CRLF>
Q=3<CRLF>
OUTERLOOP=01<CRLF>
INNERLOOP=03<CRLF>
SELECTLOOP=1<CRLF>
SELTYPE=0
LOOPDELAY=0
<CRLF>
READY><CRLF>