Setup Guide

Table Of Contents
"K" – Kill, Lock, Access Descriptors
Perform an inventory and look at the results
t61
STARTINVENTORY
TAG=3000E2001AC1909F6580000EED95 902250 00 0 E Q 0AD5
XRD0=1111111122222222
XRD1=5F7D3000E2001AC1909F6580000EED95
XRD2=E2003414011F0100
XRD3=00000000
STOPINVENTORY 0x004D EPCCOUNT=1
you can see the access password is 22222222
setup the lock descriptor to lock (not perma) the kill and access passwords. This is the 20 bit number described in the
table above.
10 Mask bits and 10 Action bits...
1010 0000 0010 1000 0000
A 0 2 8 0
Issue lock descriptor with this data
kl1a0280
ACTIVE=1
LOCKBITS=A0280
set the access password
ka22222222
ACCESSPASSWORD=22222222
Now do an inventory w/access to lock.
t61
STARTINVENTORY
TAG=3000E2001AC1909F6580000EED95 902250 01 0 E Q E573
ACCESS=SUCCESS
XRD0=1111111122222222
XRD1=5F7D3000E2001AC1909F6580000EED95
XRD2=E2003414011F0100
XRD3=00000000
LOCK=SUCCESS
STOPINVENTORY 0x0001 0x006E
Turn off access password
kar
ACCESSPASSWORD=00000000
Turn off locking
31